{"id":21552,"date":"2025-11-04T14:25:57","date_gmt":"2025-11-04T20:25:57","guid":{"rendered":"https:\/\/entrustsol.com\/?p=21552"},"modified":"2025-11-04T14:29:09","modified_gmt":"2025-11-04T20:29:09","slug":"understanding-nerc-mod-026-2","status":"publish","type":"post","link":"https:\/\/entrustsol.com\/understanding-nerc-mod-026-2\/","title":{"rendered":"Understanding NERC MOD-026-2"},"content":{"rendered":"<p><img loading=\"lazy\" decoding=\"async\" class=\" wp-image-21560\" src=\"https:\/\/entrustsol.com\/wp-content\/uploads\/2025\/11\/AdobeStock_276818539-300x200.jpg\" alt=\"\" width=\"404\" height=\"269\" srcset=\"https:\/\/entrustsol.com\/wp-content\/uploads\/2025\/11\/AdobeStock_276818539-300x200.jpg 300w, https:\/\/entrustsol.com\/wp-content\/uploads\/2025\/11\/AdobeStock_276818539-1024x683.jpg 1024w, https:\/\/entrustsol.com\/wp-content\/uploads\/2025\/11\/AdobeStock_276818539-768x513.jpg 768w, https:\/\/entrustsol.com\/wp-content\/uploads\/2025\/11\/AdobeStock_276818539-1536x1025.jpg 1536w, https:\/\/entrustsol.com\/wp-content\/uploads\/2025\/11\/AdobeStock_276818539-2048x1367.jpg 2048w, https:\/\/entrustsol.com\/wp-content\/uploads\/2025\/11\/AdobeStock_276818539-1200x801.jpg 1200w, https:\/\/entrustsol.com\/wp-content\/uploads\/2025\/11\/AdobeStock_276818539-1980x1321.jpg 1980w\" sizes=\"auto, (max-width: 404px) 100vw, 404px\" \/><\/p>\n<h3><b><span data-contrast=\"none\">Consolidation and Expansion of Dynamic Model Verification Standards<\/span><\/b><span data-ccp-props=\"{&quot;201341983&quot;:0,&quot;335559739&quot;:300,&quot;335559740&quot;:240,&quot;335572079&quot;:8,&quot;335572080&quot;:4,&quot;335572081&quot;:12419407,&quot;469789806&quot;:&quot;single&quot;}\">\u00a0<\/span><\/h3>\n<p><em>Effective Date: January 1, 2026<\/em><\/p>\n<p><span data-contrast=\"auto\">The North American Electric Reliability Corporation (NERC) has approved a major update to dynamic model verification and validation requirements. MOD-026-2\u00a0consolidates\u00a0and replaces MOD-026-1 and MOD-027-1, unifying voltage\/reactive power and frequency\/active power control into a single, comprehensive standard.<\/span><\/p>\n<p><span data-contrast=\"auto\">Driven by FERC Order No. 901, MOD-026-2 strengthens modeling requirements for Inverter-Based Resources (IBRs) such as solar, wind, and battery storage. It also expands modeling capabilities for synchronous generators, condensers, and other transmission equipment.<\/span><\/p>\n<p><b><span data-contrast=\"auto\">This standard\u00a0represents\u00a0a significant shift in reliability compliance\u2014and ENTRUST\u2019s power system experts are ready to support asset owners through every phase of implementation.<\/span><\/b><span data-ccp-props=\"{}\">\u00a0<\/span><\/p>\n<h3 aria-level=\"1\"><b><span data-contrast=\"none\">Comparison with MOD-026-1 and MOD-027-1<\/span><\/b><span data-ccp-props=\"{&quot;134245418&quot;:true,&quot;134245529&quot;:true,&quot;335559738&quot;:480,&quot;335559739&quot;:0}\">\u00a0<\/span><\/h3>\n<p><b><span data-contrast=\"auto\">Prepared:<\/span><\/b><span data-contrast=\"auto\">\u00a0October 2025<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/p>\n<p><b><span data-contrast=\"auto\">Subject:<\/span><\/b><span data-contrast=\"auto\">\u00a0Verification and Validation of Dynamic Models and Data<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/p>\n<h4 aria-level=\"2\"><b><span data-contrast=\"none\">Executive Summary<\/span><\/b><span data-ccp-props=\"{&quot;134245418&quot;:true,&quot;134245529&quot;:true,&quot;335559738&quot;:200,&quot;335559739&quot;:0}\">\u00a0<\/span><\/h4>\n<p><span data-contrast=\"auto\">MOD-026-2\u00a0consolidates\u00a0and replaces\u00a0<\/span><b><span data-contrast=\"auto\">MOD-026-1<\/span><\/b><span data-contrast=\"auto\">\u00a0(excitation\/volt-var control) and\u00a0<\/span><b><span data-contrast=\"auto\">MOD-027-1<\/span><\/b><span data-contrast=\"auto\">\u00a0(turbine\/governor control) into a single, comprehensive standard for dynamic model verification and validation. The primary driver is\u00a0<\/span><b><span data-contrast=\"auto\">FERC Order No. 901<\/span><\/b><span data-contrast=\"auto\">, which mandates better modeling of Inverter-Based Resources (IBRs) such as solar, wind, and battery storage facilities. Additionally, MOD-026-2 expands modeling capabilities by allowing Transmission Planners to optionally require limiting and protective function models for synchronous generators and condensers.<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/p>\n<h4 aria-level=\"2\"><b><span data-contrast=\"none\">Key Dates Summary<\/span><\/b><span data-ccp-props=\"{&quot;134245418&quot;:true,&quot;134245529&quot;:true,&quot;335559738&quot;:200,&quot;335559739&quot;:0}\">\u00a0<\/span><\/h4>\n<table data-tablestyle=\"Custom\" data-tablelook=\"0\" aria-rowcount=\"9\">\n<tbody>\n<tr aria-rowindex=\"1\">\n<td data-celllook=\"4369\">\n<h4><b><span data-contrast=\"auto\">Milestone<\/span><\/b><span data-ccp-props=\"{}\">\u00a0<\/span><\/h4>\n<\/td>\n<td data-celllook=\"4369\">\n<h4><b><span data-contrast=\"auto\">Timeframe<\/span><\/b><span data-ccp-props=\"{}\">\u00a0<\/span><\/h4>\n<\/td>\n<td data-celllook=\"4369\">\n<h4><b><span data-contrast=\"auto\">Description<\/span><\/b><span data-ccp-props=\"{}\">\u00a0<\/span><\/h4>\n<\/td>\n<\/tr>\n<tr aria-rowindex=\"2\">\n<td data-celllook=\"4369\"><b><span data-contrast=\"auto\">Ballot Approval<\/span><\/b><span data-ccp-props=\"{}\">\u00a0<\/span><\/td>\n<td data-celllook=\"4369\"><span data-contrast=\"auto\">October 2025<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/td>\n<td data-celllook=\"4369\"><span data-contrast=\"auto\">MOD-026-2 ballot approved<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/td>\n<\/tr>\n<tr aria-rowindex=\"3\">\n<td data-celllook=\"4369\"><b><span data-contrast=\"auto\">Regulatory Acceptance<\/span><\/b><span data-ccp-props=\"{}\">\u00a0<\/span><\/td>\n<td data-celllook=\"4369\"><span data-contrast=\"auto\">Q4 2025<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/td>\n<td data-celllook=\"4369\"><span data-contrast=\"auto\">Accepted by end of 2025<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/td>\n<\/tr>\n<tr aria-rowindex=\"4\">\n<td data-celllook=\"4369\"><b><span data-contrast=\"auto\">Effective Date<\/span><\/b><span data-ccp-props=\"{}\">\u00a0<\/span><\/td>\n<td data-celllook=\"4369\"><span data-contrast=\"auto\">January 1, 2026<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/td>\n<td data-celllook=\"4369\"><span data-contrast=\"auto\">First day of first quarter after Q4 2025 approval<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/td>\n<\/tr>\n<tr aria-rowindex=\"5\">\n<td data-celllook=\"4369\"><b><span data-contrast=\"auto\">R1 &amp; R7 Compliance<\/span><\/b><span data-ccp-props=\"{}\">\u00a0<\/span><\/td>\n<td data-celllook=\"4369\"><span data-contrast=\"auto\">January 1, 2027<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/td>\n<td data-celllook=\"4369\"><span data-contrast=\"auto\">TP\/PC develop requirements; TP provides data on request<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/td>\n<\/tr>\n<tr aria-rowindex=\"6\">\n<td data-celllook=\"4369\"><b><span data-contrast=\"auto\">R2-R6 Compliance<\/span><\/b><span data-ccp-props=\"{}\">\u00a0<\/span><\/td>\n<td data-celllook=\"4369\"><span data-contrast=\"auto\">January 1, 2029<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/td>\n<td data-celllook=\"4369\"><span data-contrast=\"auto\">Generator\/Transmission Owners\u00a0submit\u00a0verified models<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/td>\n<\/tr>\n<tr aria-rowindex=\"7\">\n<td data-celllook=\"4369\"><b><span data-contrast=\"auto\">Full Implementation<\/span><\/b><span data-ccp-props=\"{}\">\u00a0<\/span><\/td>\n<td data-celllook=\"4369\"><span data-contrast=\"auto\">January 1, 2030<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/td>\n<td data-celllook=\"4369\"><span data-contrast=\"auto\">FERC Order No. 901 deadline<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/td>\n<\/tr>\n<tr aria-rowindex=\"8\">\n<td data-celllook=\"4369\"><b><span data-contrast=\"auto\">MOD-026-1 Retirement<\/span><\/b><span data-ccp-props=\"{}\">\u00a0<\/span><\/td>\n<td data-celllook=\"4369\"><span data-contrast=\"auto\">December 31, 2025<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/td>\n<td data-celllook=\"4369\"><span data-contrast=\"auto\">Immediately prior to MOD-026-2 effective date<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/td>\n<\/tr>\n<tr aria-rowindex=\"9\">\n<td data-celllook=\"4369\"><b><span data-contrast=\"auto\">MOD-027-1 Retirement<\/span><\/b><span data-ccp-props=\"{}\">\u00a0<\/span><\/td>\n<td data-celllook=\"4369\"><span data-contrast=\"auto\">December 31, 2025<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/td>\n<td data-celllook=\"4369\"><span data-contrast=\"auto\">Immediately prior to MOD-026-2 effective date<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h4 aria-level=\"3\"><b><span data-contrast=\"none\">IMPLEMENTATION TIMELINE<\/span><\/b><span data-ccp-props=\"{&quot;134245418&quot;:true,&quot;134245529&quot;:true,&quot;335559738&quot;:200,&quot;335559739&quot;:0}\">\u00a0<\/span><\/h4>\n<p><b><span data-contrast=\"auto\">January 1,\u00a02026\u00a0\u2192 Effective Date (T\u2080)<\/span><\/b><span data-ccp-props=\"{}\">\u00a0<\/span><\/p>\n<p><span data-contrast=\"auto\">\u2193<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/p>\n<p><b><span data-contrast=\"auto\">January 1,\u00a02027\u00a0\u2192 R1 &amp; R7 Compliance (T\u2080 + 12 months)<\/span><\/b><\/p>\n<ul>\n<li>Transmission Planner\/Planning Coordinator develop model requirements<\/li>\n<li>Transmission Planner provides current models upon request<\/li>\n<\/ul>\n<p><span data-contrast=\"auto\">\u2193<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/p>\n<p><b><span data-contrast=\"auto\">January 1,\u00a02029\u00a0\u2192 R2, R3, R4, R5, R6 Compliance (T\u2080 + 36 months)<\/span><\/b><span data-ccp-props=\"{}\">\u00a0<\/span><\/p>\n<ul>\n<li><span data-contrast=\"auto\"> Generator\/Transmission Ownerssubmitverified models<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/li>\n<li><span data-contrast=\"auto\"> Model review and acceptance process<\/span><\/li>\n<li><span data-contrast=\"auto\"> Change management procedures<\/span><\/li>\n<\/ul>\n<h4><\/h4>\n<h4><b><span data-contrast=\"auto\">Submittal Timeline<\/span><\/b><span data-contrast=\"auto\">:\u00a0<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/h4>\n<p><b><span data-contrast=\"auto\">Existing Facilities\u00a0\u2013<\/span><\/b><span data-contrast=\"auto\">\u00a0Within 10 calendar years of most recent transmittal, or MOD-026-2 R2-R6 compliance date (whichever is later)<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/p>\n<p><b><span data-contrast=\"auto\">New Facilities<\/span><\/b><span data-contrast=\"auto\">\u00a0\u2013\u00a0Compliance date for R2-R6 or\u00a0365 days\u00a0after commissioning (whichever is later).<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/p>\n<p>&nbsp;<\/p>\n<h3 aria-level=\"2\"><b><span data-contrast=\"none\">Key Changes and Impacts<\/span><\/b><span data-ccp-props=\"{&quot;134245418&quot;:true,&quot;134245529&quot;:true,&quot;335559738&quot;:200,&quot;335559739&quot;:0}\">\u00a0<\/span><\/h3>\n<h4 aria-level=\"3\"><b><span data-contrast=\"none\">1. CONSOLIDATION<\/span><\/b><span data-ccp-props=\"{&quot;134245418&quot;:true,&quot;134245529&quot;:true,&quot;335559738&quot;:200,&quot;335559739&quot;:0}\">\u00a0<\/span><\/h4>\n<p><b><span data-contrast=\"auto\">Previous\u00a0Approach:<\/span><\/b><span data-ccp-props=\"{}\">\u00a0<\/span><\/p>\n<ul>\n<li><span data-contrast=\"auto\">MOD-026-1: Generator excitation control systems and plant volt\/var control<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/li>\n<li><span data-contrast=\"auto\">MOD-027-1: Turbine\/governor and load control or active power\/frequency control<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/li>\n<\/ul>\n<p><b><span data-contrast=\"auto\">New Approach:<\/span><\/b><span data-ccp-props=\"{}\">\u00a0<\/span><\/p>\n<ul>\n<li aria-setsize=\"-1\" data-leveltext=\"\uf0b7\" data-font=\"Symbol\" data-listid=\"1\" data-list-defn-props=\"{&quot;335552541&quot;:1,&quot;335559685&quot;:360,&quot;335559991&quot;:360,&quot;469769226&quot;:&quot;Symbol&quot;,&quot;469769242&quot;:[8226],&quot;469777803&quot;:&quot;left&quot;,&quot;469777804&quot;:&quot;\uf0b7&quot;,&quot;469777815&quot;:&quot;singleLevel&quot;}\" data-aria-posinset=\"3\" data-aria-level=\"1\"><span data-contrast=\"auto\">MOD-026-2:\u00a0Single standard covering both voltage\/reactive power AND frequency\/active power control<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/li>\n<\/ul>\n<p><b><span data-contrast=\"auto\">Impact:<\/span><\/b><span data-ccp-props=\"{}\">\u00a0<\/span><\/p>\n<ul>\n<li><span data-contrast=\"auto\">Streamlined compliance process<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/li>\n<li><span data-contrast=\"auto\">Single submission to Transmission Planner<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/li>\n<li><span data-contrast=\"auto\">Reduced administrative burden<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/li>\n<li><span data-contrast=\"auto\">Consistent requirements across control functions<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/li>\n<\/ul>\n<h4 aria-level=\"3\"><\/h4>\n<h4 aria-level=\"3\"><b><span data-contrast=\"none\">2. EXPANDED SCOPE\u00a0<\/span><\/b><span data-ccp-props=\"{&quot;134245418&quot;:true,&quot;134245529&quot;:true,&quot;335559738&quot;:200,&quot;335559739&quot;:0}\">\u00a0<\/span><\/h4>\n<p><b><i><span data-contrast=\"none\">Facility Types Covered:<\/span><\/i><\/b><span data-ccp-props=\"{&quot;134245418&quot;:true,&quot;134245529&quot;:true,&quot;335559738&quot;:200,&quot;335559739&quot;:0}\">\u00a0<\/span><\/p>\n<table data-tablestyle=\"Custom\" data-tablelook=\"0\" aria-rowcount=\"7\">\n<tbody>\n<tr aria-rowindex=\"1\">\n<td data-celllook=\"4369\">\n<h4><b><span data-contrast=\"auto\">Facility Type<\/span><\/b><span data-ccp-props=\"{}\">\u00a0<\/span><\/h4>\n<\/td>\n<td data-celllook=\"4369\">\n<h4><b><span data-contrast=\"auto\">Previous\u00a0Coverage<\/span><\/b><span data-ccp-props=\"{}\">\u00a0<\/span><\/h4>\n<\/td>\n<td data-celllook=\"4369\">\n<h4><b><span data-contrast=\"auto\">MOD-026-2 Coverage<\/span><\/b><span data-ccp-props=\"{}\">\u00a0<\/span><\/h4>\n<\/td>\n<\/tr>\n<tr aria-rowindex=\"2\">\n<td data-celllook=\"4369\"><b><span data-contrast=\"auto\">Synchronous Generators<\/span><\/b><span data-ccp-props=\"{}\">\u00a0<\/span><\/td>\n<td data-celllook=\"4369\"><span data-contrast=\"auto\">\u2713\u00a0Core functions<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/td>\n<td data-celllook=\"4369\"><span data-contrast=\"auto\">\u2713\u00a0Core functions + limiters\u00a0\/\u00a0protection\u00a0per TP request\u00a0<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/td>\n<\/tr>\n<tr aria-rowindex=\"3\">\n<td data-celllook=\"4369\"><b><span data-contrast=\"auto\">BES Inverter-Based Resources<\/span><\/b><span data-ccp-props=\"{}\">\u00a0<\/span><\/td>\n<td data-celllook=\"4369\"><span data-contrast=\"auto\">\u2717\u00a0Limited\/Generic<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/td>\n<td data-celllook=\"4369\"><span data-contrast=\"auto\">\u2713\u00a0Explicit &amp; Comprehensive<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/td>\n<\/tr>\n<tr aria-rowindex=\"4\">\n<td data-celllook=\"4369\"><b><span data-contrast=\"auto\">Non-BES IBRs \u226520 MVA<\/span><\/b><span data-ccp-props=\"{}\">\u00a0<\/span><\/td>\n<td data-celllook=\"4369\"><span data-contrast=\"auto\">\u2717\u00a0Not covered<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/td>\n<td data-celllook=\"4369\"><span data-contrast=\"auto\">\u2713\u00a0Explicit &amp; Comprehensive<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/td>\n<\/tr>\n<tr aria-rowindex=\"5\">\n<td data-celllook=\"4369\"><b><span data-contrast=\"auto\">HVDC Systems (LCC &amp; VSC)<\/span><\/b><span data-ccp-props=\"{}\">\u00a0<\/span><\/td>\n<td data-celllook=\"4369\"><span data-contrast=\"auto\">\u2717\u00a0Limited<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/td>\n<td data-celllook=\"4369\"><span data-contrast=\"auto\">\u2713\u00a0Explicit Requirements<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/td>\n<\/tr>\n<tr aria-rowindex=\"6\">\n<td data-celllook=\"4369\"><b><span data-contrast=\"auto\">FACTS Devices<\/span><\/b><span data-ccp-props=\"{}\">\u00a0<\/span><\/td>\n<td data-celllook=\"4369\"><span data-contrast=\"auto\">\u2717\u00a0Limited<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/td>\n<td data-celllook=\"4369\"><span data-contrast=\"auto\">\u2713\u00a0Explicit Requirements<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/td>\n<\/tr>\n<tr aria-rowindex=\"7\">\n<td data-celllook=\"4369\"><b><span data-contrast=\"auto\">Synchronous Condensers<\/span><\/b><span data-ccp-props=\"{}\">\u00a0<\/span><\/td>\n<td data-celllook=\"4369\"><span data-contrast=\"auto\">\u2713\u00a0Core functions<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/td>\n<td data-celllook=\"4369\"><span data-contrast=\"auto\">\u2713\u00a0Core functions +\u00a0limiters \/ protection\u00a0per\u00a0TP request\u00a0<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><b><i><span data-contrast=\"none\">Applicability Criteria (per MOD-026-2 Section 4):<\/span><\/i><\/b><span data-ccp-props=\"{&quot;134245418&quot;:true,&quot;134245529&quot;:true,&quot;335559738&quot;:200,&quot;335559739&quot;:0}\">\u00a0<\/span><\/p>\n<p><b><span data-contrast=\"auto\">Functional Entities:<\/span><\/b><span data-ccp-props=\"{}\">\u00a0<\/span><\/p>\n<ul>\n<li><span data-contrast=\"auto\">Generator Owner<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/li>\n<li><span data-contrast=\"auto\">Planning Coordinator<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/li>\n<li><span data-contrast=\"auto\">Transmission Owner<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/li>\n<li><span data-contrast=\"auto\">Transmission Planner<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/li>\n<\/ul>\n<p><b><span data-contrast=\"auto\">Facilities:<\/span><\/b><span data-ccp-props=\"{}\">\u00a0<\/span><\/p>\n<ol>\n<li><b><span data-contrast=\"auto\"> Synchronous Generating Units and Plants (BES Inclusion I2):<\/span><\/b><\/li>\n<\/ol>\n<ul>\n<li><span data-contrast=\"auto\">Individual synchronous generating units meeting Inclusion I2 criteria:<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/li>\n<li><span data-contrast=\"auto\">Connected at \u2265100 kV with gross individual nameplate rating &gt;20 MVA<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/li>\n<li><span data-contrast=\"auto\">Synchronous generating plants\/facilities meeting Inclusion I2 criteria:<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/li>\n<li><span data-contrast=\"auto\">Connected at \u2265100 kV with gross plant\/facility\u00a0aggregate\u00a0nameplate rating &gt;75 MVA<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/li>\n<\/ul>\n<ol start=\"2\">\n<li><b><span data-contrast=\"auto\"> Dynamic Reactive Resources (BES Inclusion I5) &gt;20 MVA:<\/span><\/b><\/li>\n<\/ol>\n<ul>\n<li><span data-contrast=\"auto\">Static or dynamic devices dedicated to supplying\/absorbing reactive power\u00a0connected at \u2265100 kV, or through dedicated transformer with\u00a0high-side\u00a0\u2265100 kV<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/li>\n<li><span data-contrast=\"auto\">Includes:\u00a0Synchronous condensers,\u00a0Flexible Alternating Current Transmission System (FACTS) devices<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/li>\n<\/ul>\n<ol start=\"3\">\n<li><b><span data-contrast=\"auto\"> High-Voltage Direct Current (HVDC) Systems:<\/span><\/b><\/li>\n<\/ol>\n<ul>\n<li><span data-contrast=\"auto\">Line Commutated Converter (LCC)<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/li>\n<li><span data-contrast=\"auto\">Voltage Source Converter (VSC)<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/li>\n<\/ul>\n<ol start=\"4\">\n<li><b><span data-contrast=\"auto\"> Inverter-Based Resources:<\/span><\/b><\/li>\n<\/ol>\n<ul>\n<li><span data-contrast=\"auto\">BES Inverter-Based Resources (all sizes)<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/li>\n<li><span data-contrast=\"auto\">Non-BES Inverter-Based Resources<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/li>\n<li><span data-contrast=\"auto\">Aggregate nameplate capacity \u226520 MVA\u00a0connected through system designed primarily for delivering such capacity\u00a0to common point of connection at voltage \u226560 kV<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/li>\n<\/ul>\n<ol start=\"5\">\n<li><b><span data-contrast=\"auto\"> Non-Synchronous Generating Plants (E.g.Type 1 &amp; 2 Wind viaBES Inclusion I4):<\/span><\/b><span data-ccp-props=\"{}\">\u00a0<\/span><\/li>\n<\/ol>\n<ul>\n<li><span data-contrast=\"auto\">Dispersed power producing resources aggregating to &gt;75 MVA (gross nameplate rating)\u00a0connected through system designed primarily for delivering such capacity\u00a0to common point of connection at voltage \u2265100 kV or above<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/li>\n<li><span data-contrast=\"auto\">Includes both:\u00a0The individual resources, AND\u00a0The system delivering capacity from aggregation point to common point of connection<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/li>\n<\/ul>\n<p><b><span data-contrast=\"none\">Detailed\u00a0Comparison\u00a0Table<\/span><\/b><span data-ccp-props=\"{&quot;134245418&quot;:true,&quot;134245529&quot;:true,&quot;335559738&quot;:200,&quot;335559739&quot;:0}\">\u00a0<\/span><\/p>\n<table data-tablestyle=\"Custom\" data-tablelook=\"0\" aria-rowcount=\"14\">\n<tbody>\n<tr aria-rowindex=\"1\">\n<td data-celllook=\"4369\">\n<h4><b><span data-contrast=\"auto\">Feature<\/span><\/b><span data-ccp-props=\"{}\">\u00a0<\/span><\/h4>\n<\/td>\n<td data-celllook=\"4369\">\n<h4><b><span data-contrast=\"auto\">MOD-026-1<\/span><\/b><span data-ccp-props=\"{}\">\u00a0<\/span><\/h4>\n<\/td>\n<td data-celllook=\"4369\">\n<h4><b><span data-contrast=\"auto\">MOD-027-1<\/span><\/b><span data-ccp-props=\"{}\">\u00a0<\/span><\/h4>\n<\/td>\n<td data-celllook=\"4369\">\n<h4><b><span data-contrast=\"auto\">MOD-026-2<\/span><\/b><span data-ccp-props=\"{}\">\u00a0<\/span><\/h4>\n<\/td>\n<\/tr>\n<tr aria-rowindex=\"2\">\n<td data-celllook=\"4369\"><b><span data-contrast=\"auto\">Functional Scope<\/span><\/b><span data-ccp-props=\"{}\">\u00a0<\/span><\/td>\n<td data-celllook=\"4369\"><span data-contrast=\"auto\">Excitation control, voltage regulation, PSS, plant volt\/var<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/td>\n<td data-celllook=\"4369\"><span data-contrast=\"auto\">Turbine\/governor, load control, active power\/frequency<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/td>\n<td data-celllook=\"4369\"><span data-contrast=\"auto\">Both combined into single standard<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/td>\n<\/tr>\n<tr aria-rowindex=\"3\">\n<td data-celllook=\"4369\"><b><span data-contrast=\"auto\">Applicable Entities<\/span><\/b><span data-ccp-props=\"{}\">\u00a0<\/span><\/td>\n<td data-celllook=\"4369\"><span data-contrast=\"auto\">Generator Owner, Transmission Planner<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/td>\n<td data-celllook=\"4369\"><span data-contrast=\"auto\">Generator Owner, Transmission Planner<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/td>\n<td data-celllook=\"4369\"><span data-contrast=\"auto\">+ Transmission Owner, Planning Coordinator<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/td>\n<\/tr>\n<tr aria-rowindex=\"4\">\n<td data-celllook=\"4369\"><b><span data-contrast=\"auto\">IBR Coverage<\/span><\/b><span data-ccp-props=\"{}\">\u00a0<\/span><\/td>\n<td data-celllook=\"4369\"><span data-contrast=\"auto\">Generic\/limited mention<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/td>\n<td data-celllook=\"4369\"><span data-contrast=\"auto\">Generic\/limited mention<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/td>\n<td data-celllook=\"4369\"><span data-contrast=\"auto\">Comprehensive &#8211; explicit requirements<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/td>\n<\/tr>\n<tr aria-rowindex=\"5\">\n<td data-celllook=\"4369\"><b><span data-contrast=\"auto\">EMT Models<\/span><\/b><span data-ccp-props=\"{}\">\u00a0<\/span><\/td>\n<td data-celllook=\"4369\"><span data-contrast=\"auto\">Not required<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/td>\n<td data-celllook=\"4369\"><span data-contrast=\"auto\">Not required<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/td>\n<td data-celllook=\"4369\"><span data-contrast=\"auto\">Required for IBRs, HVDC, FACTS<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/td>\n<\/tr>\n<tr aria-rowindex=\"6\">\n<td data-celllook=\"4369\"><b><span data-contrast=\"auto\">Positive Sequence Models<\/span><\/b><span data-ccp-props=\"{}\">\u00a0<\/span><\/td>\n<td data-celllook=\"4369\"><span data-contrast=\"auto\">Required<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/td>\n<td data-celllook=\"4369\"><span data-contrast=\"auto\">Required<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/td>\n<td data-celllook=\"4369\"><span data-contrast=\"auto\">Required (+ optional limiters\/protection for synchronous)<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/td>\n<\/tr>\n<tr aria-rowindex=\"7\">\n<td data-celllook=\"4369\"><b><span data-contrast=\"auto\">Verification Period<\/span><\/b><span data-ccp-props=\"{}\">\u00a0<\/span><\/td>\n<td data-celllook=\"4369\"><span data-contrast=\"auto\">10 years<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/td>\n<td data-celllook=\"4369\"><span data-contrast=\"auto\">10 years<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/td>\n<td data-celllook=\"4369\"><span data-contrast=\"auto\">10 years (unchanged)<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/td>\n<\/tr>\n<tr aria-rowindex=\"8\">\n<td data-celllook=\"4369\"><b><span data-contrast=\"auto\">Model Verification<\/span><\/b><span data-ccp-props=\"{}\">\u00a0<\/span><\/td>\n<td data-celllook=\"4369\"><span data-contrast=\"auto\">Implied\/informal<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/td>\n<td data-celllook=\"4369\"><span data-contrast=\"auto\">Implied\/informal<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/td>\n<td data-celllook=\"4369\"><span data-contrast=\"auto\">Explicitly defined and\u00a0required<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/td>\n<\/tr>\n<tr aria-rowindex=\"9\">\n<td data-celllook=\"4369\"><b><span data-contrast=\"auto\">Model Validation<\/span><\/b><span data-ccp-props=\"{}\">\u00a0<\/span><\/td>\n<td data-celllook=\"4369\"><span data-contrast=\"auto\">Required<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/td>\n<td data-celllook=\"4369\"><span data-contrast=\"auto\">Required<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/td>\n<td data-celllook=\"4369\"><span data-contrast=\"auto\">Required + enhanced documentation<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/td>\n<\/tr>\n<tr aria-rowindex=\"10\">\n<td data-celllook=\"4369\"><b><span data-contrast=\"auto\">GO\/TO\u00a0Change Notification<\/span><\/b><span data-ccp-props=\"{}\">\u00a0<\/span><\/td>\n<td data-celllook=\"4369\"><span data-contrast=\"auto\">180 calendar days<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/td>\n<td data-celllook=\"4369\"><span data-contrast=\"auto\">180 calendar days<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/td>\n<td data-celllook=\"4369\"><span data-contrast=\"auto\">180 calendar days (unchanged)<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/td>\n<\/tr>\n<tr aria-rowindex=\"11\">\n<td data-celllook=\"4369\"><b><span data-contrast=\"auto\">Response Timeline\u00a0<\/span><\/b><span data-ccp-props=\"{}\">\u00a0<\/span><\/td>\n<td data-celllook=\"4369\"><span data-contrast=\"auto\">90 calendar days<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/td>\n<td data-celllook=\"4369\"><span data-contrast=\"auto\">90 calendar days<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/td>\n<td data-celllook=\"4369\"><span data-contrast=\"auto\">120\u00a0calendar days*\u00a0<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/td>\n<\/tr>\n<tr aria-rowindex=\"12\">\n<td data-celllook=\"4369\"><b><span data-contrast=\"auto\">Equivalent Unit Provision (synchronous only)<\/span><\/b><span data-ccp-props=\"{}\">\u00a0<\/span><\/td>\n<td data-celllook=\"4369\"><span data-contrast=\"auto\">\u2264350 MVA, same components<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/td>\n<td data-celllook=\"4369\"><span data-contrast=\"auto\">\u2264350 MVA, same components<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/td>\n<td data-celllook=\"4369\"><span data-contrast=\"auto\">\u2264350 MVA, same components (unchanged)<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/td>\n<\/tr>\n<tr aria-rowindex=\"13\">\n<td data-celllook=\"4369\"><b><span data-contrast=\"auto\">Low Capacity\u00a0Factor Exemption<\/span><\/b><span data-ccp-props=\"{}\">\u00a0<\/span><\/td>\n<td data-celllook=\"4369\"><span data-contrast=\"auto\">\u22645% over 3 years<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/td>\n<td data-celllook=\"4369\"><span data-contrast=\"auto\">\u22645% over 3 years<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/td>\n<td data-celllook=\"4369\"><span data-contrast=\"auto\">\u22645% over 3 years (unchanged)<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/td>\n<\/tr>\n<tr aria-rowindex=\"14\">\n<td data-celllook=\"4369\"><b><span data-contrast=\"auto\">Jointly Developed Requirements<\/span><\/b><span data-ccp-props=\"{}\">\u00a0<\/span><\/td>\n<td data-celllook=\"4369\"><span data-contrast=\"auto\">No<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/td>\n<td data-celllook=\"4369\"><span data-contrast=\"auto\">No<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/td>\n<td data-celllook=\"4369\"><span data-contrast=\"auto\">Yes &#8211; TP &amp; PC must jointly develop (R1)<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><span data-contrast=\"auto\">*120 days\u00a0for\u00a0TP response to\u00a0new model transmittal (R5), GO response to unacceptability\u00a0R6).\u00a0<\/span><br \/>\n<span data-contrast=\"auto\">TP to provide\u00a0existing\u00a0model within\u00a090 days\u00a0of request (R7).<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/p>\n<p>&nbsp;<\/p>\n<h4 aria-level=\"3\"><b><span data-contrast=\"none\">3. NEW REQUIREMENT: ELECTROMAGNETIC TRANSIENT (EMT) MODELS\u00a0FOR IBR<\/span><\/b><span data-ccp-props=\"{&quot;134245418&quot;:true,&quot;134245529&quot;:true,&quot;335559738&quot;:200,&quot;335559739&quot;:0}\">\u00a0<\/span><\/h4>\n<p><b><i><span data-contrast=\"none\">Requirement R3 (NEW in MOD-026-2)<\/span><\/i><\/b><span data-ccp-props=\"{&quot;134245418&quot;:true,&quot;134245529&quot;:true,&quot;335559738&quot;:200,&quot;335559739&quot;:0}\">\u00a0<\/span><\/p>\n<p><b><span data-contrast=\"auto\">What&#8217;s Required:<\/span><\/b><span data-ccp-props=\"{}\">\u00a0<\/span><\/p>\n<p><span data-contrast=\"auto\">Generator Owners and Transmission Owners must provide\u00a0<\/span><b><span data-contrast=\"auto\">EMT models<\/span><\/b><span data-contrast=\"auto\">\u00a0for:<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/p>\n<ul>\n<li><span data-contrast=\"auto\">Inverter-Based Resources (solar, wind, battery storage)<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/li>\n<li><span data-contrast=\"auto\">FACTS devices<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/li>\n<li><span data-contrast=\"auto\">HVDC systems (both LCC and VSC types)<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/li>\n<\/ul>\n<p><b><span data-contrast=\"auto\">Exclusions:<\/span><\/b><span data-ccp-props=\"{}\">\u00a0<\/span><\/p>\n<ul>\n<li><span data-contrast=\"auto\">Legacy facilities where original equipment manufacturer no longer supports EMT models<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/li>\n<li><span data-contrast=\"auto\">Legacy facilities NOT\u00a0identified\u00a0by Transmission Planner as requiring EMT models (per R1, Part 1.2.1)<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/li>\n<\/ul>\n<p><b><i><span data-contrast=\"none\">EMT Model Components (R3.1):<\/span><\/i><\/b><span data-ccp-props=\"{&quot;134245418&quot;:true,&quot;134245529&quot;:true,&quot;335559738&quot;:200,&quot;335559739&quot;:0}\">\u00a0<\/span><\/p>\n<p><span data-contrast=\"auto\">Must include\u00a0integrated plant model with components\u00a0representing:<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/p>\n<ul>\n<li><span data-contrast=\"auto\">IBR unit(s)<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/li>\n<li><span data-contrast=\"auto\">Collector system<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/li>\n<li><span data-contrast=\"auto\">Auxiliary control devices (acting on voltage\/frequency)<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/li>\n<li><span data-contrast=\"auto\">Power plant controller<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/li>\n<li><span data-contrast=\"auto\">Generator step-up transformer(s)<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/li>\n<li><span data-contrast=\"auto\">Main power transformer(s)<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/li>\n<li><span data-contrast=\"auto\">Enabled protective functions\u00a0that directly trip units\/facility<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/li>\n<li><span data-contrast=\"auto\">Limiting functions\u00a0that limit active\/reactive output<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/li>\n<\/ul>\n<p><b><i><span data-contrast=\"none\">Required Documentation (R3.2-R3.5):<\/span><\/i><\/b><span data-ccp-props=\"{&quot;134245418&quot;:true,&quot;134245529&quot;:true,&quot;335559738&quot;:200,&quot;335559739&quot;:0}\">\u00a0<\/span><\/p>\n<ul>\n<li><span data-contrast=\"auto\">Model Verification- Configurable parameters match design\/settings<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/li>\n<li><span data-contrast=\"auto\">Model Validation- Comparison with measured behavior during:<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/li>\n<li><span data-contrast=\"auto\">Voltage excursion\u00a0or staged test\u00a0events<\/span><span data-ccp-props=\"{&quot;335559685&quot;:720,&quot;469777462&quot;:[360,720],&quot;469777927&quot;:[0,0],&quot;469777928&quot;:[0,8]}\">\u00a0<\/span><\/li>\n<li><span data-contrast=\"auto\">Frequency excursion\u00a0or staged test\u00a0events<\/span><span data-ccp-props=\"{&quot;335559685&quot;:720,&quot;469777462&quot;:[360,720],&quot;469777927&quot;:[0,0],&quot;469777928&quot;:[0,8]}\">\u00a0<\/span><\/li>\n<li><span data-contrast=\"auto\">Unit-Level Testing* (R3.4) &#8211; Factory\/Hardware-in-Loop testing for large signal disturbances\u00a0[*typically performed by OEM]<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/li>\n<li><span data-contrast=\"auto\">Cross-Validation (R3.5) &#8211; Comparison between EMT and positive sequence model responses<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/li>\n<\/ul>\n<p><b><span data-contrast=\"none\">This\u00a0represents\u00a0a significant new technical and cost burden for IBR facilities.<\/span><\/b><span data-ccp-props=\"{}\">\u00a0<\/span><\/p>\n<p>&nbsp;<\/p>\n<h4 aria-level=\"3\"><b><span data-contrast=\"none\">4. DUAL MODELING REQUIREMENT FOR IBRs<\/span><\/b><span data-ccp-props=\"{&quot;134245418&quot;:true,&quot;134245529&quot;:true,&quot;335559738&quot;:200,&quot;335559739&quot;:0}\">\u00a0<\/span><\/h4>\n<p><span data-contrast=\"auto\">Applicable IBR facilities must provide\u00a0<\/span><b><span data-contrast=\"auto\">BOTH<\/span><\/b><span data-contrast=\"auto\">:<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/p>\n<p><b><i><span data-contrast=\"none\">Requirement R2: Positive Sequence Dynamic Models<\/span><\/i><\/b><span data-ccp-props=\"{&quot;134245418&quot;:true,&quot;134245529&quot;:true,&quot;335559738&quot;:200,&quot;335559739&quot;:0}\">\u00a0<\/span><\/p>\n<ul>\n<li><span data-contrast=\"auto\">Traditional phasor-domain models<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/li>\n<li><span data-contrast=\"auto\">Used for bulk system stability studies<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/li>\n<li><span data-contrast=\"auto\">10-year verification cycle<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/li>\n<\/ul>\n<p><b><i><span data-contrast=\"none\">Requirement R3: EMT Models<\/span><\/i><\/b><span data-ccp-props=\"{&quot;134245418&quot;:true,&quot;134245529&quot;:true,&quot;335559738&quot;:200,&quot;335559739&quot;:0}\">\u00a0<\/span><\/p>\n<ul>\n<li><span data-contrast=\"auto\">Time-domain electromagnetic transient models<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/li>\n<li><span data-contrast=\"auto\">More detailed representation<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/li>\n<li><span data-contrast=\"auto\">Includes fast dynamics and switching behavior<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/li>\n<li><span data-contrast=\"auto\">10-year verification cycle (same as R2)<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/li>\n<\/ul>\n<p><b><i><span data-contrast=\"none\">Requirement R3.5: Model Comparison<\/span><\/i><\/b><span data-ccp-props=\"{&quot;134245418&quot;:true,&quot;134245529&quot;:true,&quot;335559738&quot;:200,&quot;335559739&quot;:0}\">\u00a0<\/span><\/p>\n<ul>\n<li><span data-contrast=\"auto\">Documentation comparing responses between both model types<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/li>\n<li><span data-contrast=\"auto\">Demonstrates consistency for large signal disturbances<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/li>\n<\/ul>\n<h4 aria-level=\"3\"><\/h4>\n<h4 aria-level=\"3\"><b><span data-contrast=\"none\">5. CLARIFIED TERMINOLOGY<\/span><\/b><span data-ccp-props=\"{&quot;134245418&quot;:true,&quot;134245529&quot;:true,&quot;335559738&quot;:200,&quot;335559739&quot;:0}\">\u00a0<\/span><\/h4>\n<p><span data-contrast=\"auto\">MOD-026-2 introduces\u00a0<\/span><b><span data-contrast=\"auto\">formal definitions<\/span><\/b><span data-contrast=\"auto\">\u00a0(adopted by NERC Board August 2025):<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/p>\n<table data-tablestyle=\"Custom\" data-tablelook=\"0\" aria-rowcount=\"3\">\n<tbody>\n<tr aria-rowindex=\"1\">\n<td data-celllook=\"4369\">\n<h4><b><span data-contrast=\"auto\">Term<\/span><\/b><span data-ccp-props=\"{}\">\u00a0<\/span><\/h4>\n<\/td>\n<td data-celllook=\"4369\">\n<h4><b><span data-contrast=\"auto\">Definition<\/span><\/b><span data-ccp-props=\"{}\">\u00a0<\/span><\/h4>\n<\/td>\n<td data-celllook=\"4369\">\n<h4><b><span data-contrast=\"auto\">Previous\u00a0Standards<\/span><\/b><span data-ccp-props=\"{}\">\u00a0<\/span><\/h4>\n<\/td>\n<\/tr>\n<tr aria-rowindex=\"2\">\n<td data-celllook=\"4369\"><b><span data-contrast=\"auto\">Model Verification<\/span><\/b><span data-ccp-props=\"{}\">\u00a0<\/span><\/td>\n<td data-celllook=\"4369\"><span data-contrast=\"auto\">Process of confirming model structure and parameters\u00a0are\u00a0representative of equipment design and settings by reviewing documentation<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/td>\n<td data-celllook=\"4369\"><span data-contrast=\"auto\">Used informally, not formally defined<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/td>\n<\/tr>\n<tr aria-rowindex=\"3\">\n<td data-celllook=\"4369\"><b><span data-contrast=\"auto\">Model Validation<\/span><\/b><span data-ccp-props=\"{}\">\u00a0<\/span><\/td>\n<td data-celllook=\"4369\"><span data-contrast=\"auto\">Process of comparing simulation results with measurements to assess how closely model behavior matches measured behavior<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/td>\n<td data-celllook=\"4369\"><span data-contrast=\"auto\">Used informally, not formally defined<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><b><span data-contrast=\"auto\">Impact:<\/span><\/b><span data-contrast=\"auto\">\u00a0Clear distinction between:<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/p>\n<ul>\n<li><span data-contrast=\"auto\">Verification = checking against design documentation<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/li>\n<li><span data-contrast=\"auto\">Validation = checking against actual performance measurements<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/li>\n<\/ul>\n<p><span data-contrast=\"auto\">Note\u00a0that\u00a0per these definitions, validation data\u00a0(i.e.\u00a0from an external party)\u00a0can be an input to verification.\u00a0<\/span><span data-ccp-props=\"{&quot;335559685&quot;:360,&quot;335559991&quot;:360}\">\u00a0<\/span><\/p>\n<p><span data-ccp-props=\"{&quot;335559685&quot;:360,&quot;335559991&quot;:360}\">\u00a0<\/span><\/p>\n<h4 aria-level=\"3\"><b><span data-contrast=\"none\">6. ENHANCED MODEL REQUIREMENTS<\/span><\/b><span data-ccp-props=\"{&quot;134245418&quot;:true,&quot;134245529&quot;:true,&quot;335559738&quot;:200,&quot;335559739&quot;:0}\">\u00a0<\/span><\/h4>\n<p><b><i><span data-contrast=\"none\">Comparison of Requirements:<\/span><\/i><\/b><span data-ccp-props=\"{&quot;134245418&quot;:true,&quot;134245529&quot;:true,&quot;335559738&quot;:200,&quot;335559739&quot;:0}\">\u00a0<\/span><\/p>\n<table data-tablestyle=\"Custom\" data-tablelook=\"0\" aria-rowcount=\"9\">\n<tbody>\n<tr aria-rowindex=\"1\">\n<td data-celllook=\"4369\">\n<h4><b><span data-contrast=\"auto\">Aspect<\/span><\/b><span data-ccp-props=\"{}\">\u00a0<\/span><\/h4>\n<\/td>\n<td data-celllook=\"4369\">\n<h4><b><span data-contrast=\"auto\">MOD-026-1\/027-1<\/span><\/b><span data-ccp-props=\"{}\">\u00a0<\/span><\/h4>\n<\/td>\n<td data-celllook=\"4369\">\n<h4><b><span data-contrast=\"auto\">MOD-026-2<\/span><\/b><span data-ccp-props=\"{}\">\u00a0<\/span><\/h4>\n<\/td>\n<\/tr>\n<tr aria-rowindex=\"2\">\n<td data-celllook=\"4369\"><b><span data-contrast=\"auto\">Voltage\/Reactive Power\u00a0Validation<\/span><\/b><span data-ccp-props=\"{}\">\u00a0<\/span><\/td>\n<td data-celllook=\"4369\"><span data-contrast=\"auto\">Voltage excursion test\u00a0required<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/td>\n<td data-celllook=\"4369\"><span data-contrast=\"auto\">Same, plus enhanced documentation<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/td>\n<\/tr>\n<tr aria-rowindex=\"3\">\n<td data-celllook=\"4369\"><b><span data-contrast=\"auto\">Frequency\/Active Power\u00a0Validation<\/span><\/b><span data-ccp-props=\"{}\">\u00a0<\/span><\/td>\n<td data-celllook=\"4369\"><span data-contrast=\"auto\">Frequency excursion test\u00a0required<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/td>\n<td data-celllook=\"4369\"><span data-contrast=\"auto\">Same test\u00a0required, with updated thresholds (reduced for most interconnections)<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/td>\n<\/tr>\n<tr aria-rowindex=\"4\">\n<td data-celllook=\"4369\"><b><span data-contrast=\"auto\">IBR Unit-Level\u00a0Validation<\/span><\/b><span data-ccp-props=\"{}\">\u00a0<\/span><b><span data-contrast=\"auto\">[typically performed by OEMs in factory]<\/span><\/b><span data-ccp-props=\"{}\">\u00a0<\/span><\/td>\n<td data-celllook=\"4369\"><span data-contrast=\"auto\">Not addressed<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/td>\n<td data-celllook=\"4369\"><span data-contrast=\"auto\">\u00a0Factory\/HIL testing\u00a0documentation\u00a0required (R3.4)<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/td>\n<\/tr>\n<tr aria-rowindex=\"5\">\n<td data-celllook=\"4369\"><b><span data-contrast=\"auto\">Protective Function\u00a0Verification\u00a0&#8211; Synchronous<\/span><\/b><span data-ccp-props=\"{}\">\u00a0<\/span><\/td>\n<td data-celllook=\"4369\"><span data-contrast=\"auto\">Not addressed<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/td>\n<td data-celllook=\"4369\"><span data-contrast=\"auto\">Optional per TP requirements (Table 1.1 &#8211; NEW)<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/td>\n<\/tr>\n<tr aria-rowindex=\"6\">\n<td data-celllook=\"4369\"><b><span data-contrast=\"auto\">Protective Function\u00a0Verification\u00a0&#8211; IBRs<\/span><\/b><span data-ccp-props=\"{}\">\u00a0<\/span><\/td>\n<td data-celllook=\"4369\"><span data-contrast=\"auto\">Not addressed<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/td>\n<td data-celllook=\"4369\"><span data-contrast=\"auto\">Required (explicitly listed in Table 1.2)<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/td>\n<\/tr>\n<tr aria-rowindex=\"7\">\n<td data-celllook=\"4369\"><b><span data-contrast=\"auto\">Limiting Function\u00a0Verification\u00a0&#8211; Synchronous<\/span><\/b><span data-ccp-props=\"{}\">\u00a0<\/span><\/td>\n<td data-celllook=\"4369\"><span data-contrast=\"auto\">Optional\/implied<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/td>\n<td data-celllook=\"4369\"><span data-contrast=\"auto\">Optional per TP requirements (Table 1.1 &#8211; NEW)<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/td>\n<\/tr>\n<tr aria-rowindex=\"8\">\n<td data-celllook=\"4369\"><b><span data-contrast=\"auto\">Limiting Function\u00a0Verification\u00a0&#8211; IBRs<\/span><\/b><span data-ccp-props=\"{}\">\u00a0<\/span><\/td>\n<td data-celllook=\"4369\"><span data-contrast=\"auto\">Not addressed<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/td>\n<td data-celllook=\"4369\"><span data-contrast=\"auto\">Required (explicitly listed in Table 1.2)<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/td>\n<\/tr>\n<tr aria-rowindex=\"9\">\n<td data-celllook=\"4369\"><b><span data-contrast=\"auto\">EMT vs. Positive Sequence\u00a0Verification<\/span><\/b><span data-ccp-props=\"{}\">\u00a0<\/span><\/td>\n<td data-celllook=\"4369\"><span data-contrast=\"auto\">N\/A<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/td>\n<td data-celllook=\"4369\"><span data-contrast=\"auto\">Benchmark\u00a0(comparison)\u00a0required\u00a0(R3.5)<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>&nbsp;<\/p>\n<p><b><i><span data-contrast=\"none\">Frequency Excursion Thresholds (changed from MOD-027-1):<\/span><\/i><\/b><span data-ccp-props=\"{&quot;134245418&quot;:true,&quot;134245529&quot;:true,&quot;335559738&quot;:200,&quot;335559739&quot;:0}\">\u00a0<\/span><\/p>\n<p><span data-contrast=\"auto\">Facility must be\u00a0operating\u00a0in frequency-responsive mode with frequency deviation (nadir) from scheduled frequency \u2265:<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/p>\n<table data-tablestyle=\"Custom\" data-tablelook=\"0\" aria-rowcount=\"5\">\n<tbody>\n<tr aria-rowindex=\"1\">\n<td data-celllook=\"4369\">\n<h4><b><span data-contrast=\"auto\">Interconnection<\/span><\/b><span data-ccp-props=\"{}\">\u00a0<\/span><\/h4>\n<\/td>\n<td data-celllook=\"4369\">\n<h4><b><span data-contrast=\"auto\">Threshold<\/span><\/b><span data-ccp-props=\"{}\">\u00a0<\/span><\/h4>\n<\/td>\n<\/tr>\n<tr aria-rowindex=\"2\">\n<td data-celllook=\"4369\"><b><span data-contrast=\"auto\">Eastern<\/span><\/b><span data-ccp-props=\"{}\">\u00a0<\/span><\/td>\n<td data-celllook=\"4369\"><span data-contrast=\"auto\">0.04 Hz\u00a0<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/td>\n<\/tr>\n<tr aria-rowindex=\"3\">\n<td data-celllook=\"4369\"><b><span data-contrast=\"auto\">ERCOT<\/span><\/b><span data-ccp-props=\"{}\">\u00a0<\/span><\/td>\n<td data-celllook=\"4369\"><span data-contrast=\"auto\">0.08 Hz\u00a0<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/td>\n<\/tr>\n<tr aria-rowindex=\"4\">\n<td data-celllook=\"4369\"><b><span data-contrast=\"auto\">Western<\/span><\/b><span data-ccp-props=\"{}\">\u00a0<\/span><\/td>\n<td data-celllook=\"4369\"><span data-contrast=\"auto\">0.08 Hz\u00a0<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/td>\n<\/tr>\n<tr aria-rowindex=\"5\">\n<td data-celllook=\"4369\"><b><span data-contrast=\"auto\">Quebec<\/span><\/b><span data-ccp-props=\"{}\">\u00a0<\/span><\/td>\n<td data-celllook=\"4369\"><span data-contrast=\"auto\">0.30 Hz\u00a0<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><b><span data-contrast=\"auto\">Note:<\/span><\/b><span data-contrast=\"auto\">\u00a0MOD-026-2 reduced thresholds for Eastern (0.05\u21920.04 Hz), ERCOT (0.10\u21920.08 Hz), and Western (0.10\u21920.08 Hz) interconnections, making it easier to find qualifying frequency events for validation purposes. Quebec&#8217;s threshold was increased (0.15\u21920.30 Hz).<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/p>\n<p>&nbsp;<\/p>\n<h3 aria-level=\"1\"><b><span data-contrast=\"none\">User Guidance by\u00a0Asset Owners\u00a0<\/span><\/b><span data-ccp-props=\"{&quot;134245418&quot;:true,&quot;134245529&quot;:true,&quot;335559738&quot;:480,&quot;335559739&quot;:0}\">\u00a0<\/span><\/h3>\n<h4 aria-level=\"4\"><b><i><span data-contrast=\"none\">1.\u00a0Determine\u00a0Applicability<\/span><\/i><\/b><span data-ccp-props=\"{&quot;134245418&quot;:true,&quot;134245529&quot;:true,&quot;335559738&quot;:200,&quot;335559739&quot;:0}\">\u00a0<\/span><\/h4>\n<p><b><span data-contrast=\"auto\">Action Items:<\/span><\/b><span data-ccp-props=\"{}\">\u00a0<\/span><\/p>\n<ul>\n<li><span data-contrast=\"auto\">Review MOD-026-2 Section 4.2 (Facilities) carefully<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/li>\n<li><span data-contrast=\"auto\">Identify\u00a0newly applicable units, particularly:<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/li>\n<li><span data-contrast=\"auto\">BES\u00a0Synchronous or\u00a0Inverter-Based Resources (any size)<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/li>\n<li><span data-contrast=\"auto\">Non-BES IBRs \u226520 MVA connected at \u226560 kV<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/li>\n<li><span data-contrast=\"auto\">Non-synchronous generating plants meeting BES definition<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/li>\n<li><span data-contrast=\"auto\">HVDC systems (LCC and VSC)<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/li>\n<li><span data-contrast=\"auto\">FACTS devices &gt;20 MVA<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/li>\n<\/ul>\n<h4 aria-level=\"4\"><b><i><span data-contrast=\"none\">2. EMT Model Preparation\u00a0\u2013 IBR Only\u00a0(CRITICAL PATH)<\/span><\/i><\/b><span data-ccp-props=\"{&quot;134245418&quot;:true,&quot;134245529&quot;:true,&quot;335559738&quot;:200,&quot;335559739&quot;:0}\">\u00a0<\/span><\/h4>\n<p><b><span data-contrast=\"auto\">Immediate Actions (HIGH PRIORITY):<\/span><\/b><span data-ccp-props=\"{}\">\u00a0<\/span><\/p>\n<ul>\n<li aria-setsize=\"-1\" data-leveltext=\"\uf0b7\" data-font=\"Symbol\" data-listid=\"1\" data-list-defn-props=\"{&quot;335552541&quot;:1,&quot;335559685&quot;:360,&quot;335559991&quot;:360,&quot;469769226&quot;:&quot;Symbol&quot;,&quot;469769242&quot;:[8226],&quot;469777803&quot;:&quot;left&quot;,&quot;469777804&quot;:&quot;\uf0b7&quot;,&quot;469777815&quot;:&quot;singleLevel&quot;}\" data-aria-posinset=\"48\" data-aria-level=\"1\"><span data-contrast=\"auto\">Legacy equipment may qualify for exemption if manufacturer no longer provides support<\/span><span data-ccp-props=\"{&quot;335559685&quot;:720,&quot;469777462&quot;:[360,720],&quot;469777927&quot;:[0,0],&quot;469777928&quot;:[0,8]}\">\u00a0<\/span><\/li>\n<li><span data-contrast=\"auto\">Model Acquisition: Contact Equipment Manufacturers<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/li>\n<li><span data-contrast=\"auto\">Identify\u00a0OEM support status of equipment.\u00a0<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/li>\n<li><span data-contrast=\"auto\">If possible, obtain EMT models\u00a0or model information\u00a0for:<\/span><span data-ccp-props=\"{}\">\u00a0<\/span>\n<ul>\n<li><span data-contrast=\"auto\">IBR inverter units<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/li>\n<li><span data-contrast=\"auto\">Power plant controller<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/li>\n<li><span data-contrast=\"auto\">Transformers (GSU and main power\u00a0saturation curves)<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/li>\n<\/ul>\n<\/li>\n<li><span data-contrast=\"auto\">Testing Requirements:<\/span><span data-ccp-props=\"{}\">\u00a0<\/span>\n<ul>\n<li><span data-contrast=\"auto\">Budget for testing costs\u00a0<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/li>\n<li><span data-contrast=\"auto\">Schedule testing during commissioning for new facilities<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/li>\n<\/ul>\n<\/li>\n<li><span data-contrast=\"auto\">Model Verification:<\/span><span data-ccp-props=\"{}\">\u00a0<\/span>\n<ul>\n<li><span data-contrast=\"auto\">Collect equipment design specifications<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/li>\n<li><span data-contrast=\"auto\">Obtain control system settings documentation<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/li>\n<li><span data-contrast=\"auto\">Maintain software\/firmware version records<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/li>\n<\/ul>\n<\/li>\n<\/ul>\n<p><b><span data-contrast=\"auto\">Timeline:<\/span><\/b><span data-ccp-props=\"{}\">\u00a0<\/span><\/p>\n<ul>\n<li><span data-contrast=\"auto\">Begin in Q1 2026 (do not wait for Transmission Planner requirements)<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/li>\n<li><span data-contrast=\"auto\">Lead time for manufacturer EMT models: months typical<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/li>\n<li><span data-contrast=\"auto\">Preliminary analysis\u00a0and test coordination: 3-6 months<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/li>\n<li><span data-contrast=\"auto\">Target completion: January 2027 (24 months\u00a0before January 1,\u00a02029\u00a0R3 compliance deadline)<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/li>\n<\/ul>\n<p><span data-ccp-props=\"{}\">\u00a0<\/span><\/p>\n<h4 aria-level=\"4\"><b><i><span data-contrast=\"none\">3. Timeline Planning<\/span><\/i><\/b><span data-ccp-props=\"{&quot;134245418&quot;:true,&quot;134245529&quot;:true,&quot;335559738&quot;:200,&quot;335559739&quot;:0}\">\u00a0<\/span><\/h4>\n<p><b><span data-contrast=\"auto\">Recommended Project Schedule:<\/span><\/b><span data-ccp-props=\"{}\">\u00a0<\/span><\/p>\n<table data-tablestyle=\"Custom\" data-tablelook=\"0\" aria-rowcount=\"5\">\n<tbody>\n<tr aria-rowindex=\"1\">\n<td data-celllook=\"4369\">\n<h4><b><span data-contrast=\"auto\">Timeframe<\/span><\/b><span data-ccp-props=\"{}\">\u00a0<\/span><\/h4>\n<\/td>\n<td data-celllook=\"4369\">\n<h4><b><span data-contrast=\"auto\">Activities<\/span><\/b><span data-ccp-props=\"{}\">\u00a0<\/span><\/h4>\n<\/td>\n<\/tr>\n<tr aria-rowindex=\"2\">\n<td data-celllook=\"4369\"><b><span data-contrast=\"auto\">January 2026 &#8211; December 2026<\/span><\/b><span data-ccp-props=\"{}\">\u00a0<\/span><b><span data-contrast=\"auto\">(Year 1)<\/span><\/b><span data-ccp-props=\"{}\">\u00a0<\/span><\/td>\n<td data-celllook=\"4369\">\n<ul>\n<li><span data-contrast=\"auto\">Monitor for Transmission Planner model requirements (R1 due January 2027)<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/li>\n<li><span data-contrast=\"auto\">Initiate manufacturer contact for EMT models<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/li>\n<li><span data-contrast=\"auto\">Review facility applicability<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/li>\n<li><span data-contrast=\"auto\">Identify equivalent units (if applicable)<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/li>\n<\/ul>\n<\/td>\n<\/tr>\n<tr aria-rowindex=\"3\">\n<td data-celllook=\"4369\"><b><span data-contrast=\"auto\">January 2027 &#8211; December 2027<\/span><\/b><span data-ccp-props=\"{}\">\u00a0<\/span><b><span data-contrast=\"auto\">(Year 2)<\/span><\/b><span data-ccp-props=\"{}\">\u00a0<\/span><\/td>\n<td data-celllook=\"4369\">\n<ul>\n<li><span data-contrast=\"auto\">Receive TP model requirements (by January 2027)<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/li>\n<li><span data-contrast=\"auto\">Obtain EMT and positive sequence models<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/li>\n<li><span data-contrast=\"auto\">Schedule validation testing<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/li>\n<li><span data-contrast=\"auto\">Compile verification documentation<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/li>\n<\/ul>\n<\/td>\n<\/tr>\n<tr aria-rowindex=\"4\">\n<td data-celllook=\"4369\"><b><span data-contrast=\"auto\">January 2028 &#8211; December 2028<\/span><\/b><span data-ccp-props=\"{}\">\u00a0<\/span><b><span data-contrast=\"auto\">(Year 3)<\/span><\/b><span data-ccp-props=\"{}\">\u00a0<\/span><\/td>\n<td data-celllook=\"4369\">\n<ul>\n<li><span data-contrast=\"auto\">Complete validation testing<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/li>\n<li><span data-contrast=\"auto\">Prepare comparison documentation (R3.5 for IBRs)<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/li>\n<li><span data-contrast=\"auto\">Quality review of submittals<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/li>\n<li><span data-contrast=\"auto\">Submit to Transmission Planner by January 1, 2029<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/li>\n<\/ul>\n<\/td>\n<\/tr>\n<tr aria-rowindex=\"5\">\n<td data-celllook=\"4369\"><b><span data-contrast=\"auto\">Ongoing<\/span><\/b><span data-ccp-props=\"{}\">\u00a0<\/span><\/td>\n<td data-celllook=\"4369\">\n<ul>\n<li><span data-contrast=\"auto\">Monitor equipment changes<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/li>\n<li><span data-contrast=\"auto\">180-day notification for changes altering dynamic response (R4)<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/li>\n<li><span data-contrast=\"auto\">Respond to TP comments within 120 days (R3)<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/li>\n<\/ul>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><span data-ccp-props=\"{}\">\u00a0<\/span><\/p>\n<h3 aria-level=\"1\"><b><span data-contrast=\"none\">Common Questions &amp; Answers<\/span><\/b><span data-ccp-props=\"{&quot;134245418&quot;:true,&quot;134245529&quot;:true,&quot;335559738&quot;:480,&quot;335559739&quot;:0}\">\u00a0<\/span><\/h3>\n<p><b><span data-contrast=\"none\">Q1: If I have multiple identical wind turbines, do I need an EMT model for each turbine?<\/span><\/b><span data-ccp-props=\"{&quot;134245418&quot;:true,&quot;134245529&quot;:true,&quot;335559738&quot;:200,&quot;335559739&quot;:0}\">\u00a0<\/span><\/p>\n<p><b><span data-contrast=\"auto\">A:<\/span><\/b><span data-contrast=\"auto\">\u00a0No. MOD-026-2 allows\u00a0<\/span><b><span data-contrast=\"auto\">aggregate modeling<\/span><\/b><span data-contrast=\"auto\">\u00a0for units &lt;20 MVA in a generating plant. You may provide:<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/p>\n<ul>\n<li><span data-contrast=\"auto\">Individual unit model, OR<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/li>\n<li><span data-contrast=\"auto\">Aggregate unit model\u00a0representing\u00a0multiple identical units<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/li>\n<\/ul>\n<p><span data-contrast=\"auto\">The key is that the model must\u00a0represent\u00a0the facility&#8217;s dynamic behavior at the point of interconnection. Typically, one representative turbine model is used with\u00a0appropriate scaling.<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/p>\n<p>&nbsp;<\/p>\n<p><b><span data-contrast=\"none\">Q2: If I have multiple types of wind turbines or inverters, do I need an EMT model for each turbine?<\/span><\/b><span data-ccp-props=\"{&quot;134245418&quot;:true,&quot;134245529&quot;:true,&quot;335559738&quot;:200,&quot;335559739&quot;:0}\">\u00a0<\/span><\/p>\n<p><b><span data-contrast=\"auto\">A<\/span><\/b><span data-contrast=\"auto\">: Yes. Each IBR unit must have explicit representation as well as parameterization. Each OEM should be contacted.<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/p>\n<p>&nbsp;<\/p>\n<p><b><span data-contrast=\"none\">Q3: What if my IBR Unit (wind turbine or inverter) has an EMT model available, but my Power Plant Controller OEM does not have a model available?<\/span><\/b><span data-ccp-props=\"{&quot;134245418&quot;:true,&quot;134245529&quot;:true,&quot;335559738&quot;:200,&quot;335559739&quot;:0}\">\u00a0<\/span><\/p>\n<p><b><span data-contrast=\"auto\">A<\/span><\/b><span data-contrast=\"auto\">: The controls experts at ENTRUST can build custom PPC models based on documentation and measured results, then use this as input to R3.\u00a0<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/p>\n<p>&nbsp;<\/p>\n<p><b><span data-contrast=\"none\">Q4: What is the best way to get data for validation (comparison between measurement and model results)?<\/span><\/b><span data-ccp-props=\"{&quot;134245418&quot;:true,&quot;134245529&quot;:true,&quot;335559738&quot;:200,&quot;335559739&quot;:0}\">\u00a0<\/span><\/p>\n<p><b><span data-contrast=\"auto\">A<\/span><\/b><span data-contrast=\"auto\">: Staged testing is the most effective\u00a0manner\u00a0to\u00a0validate\u00a0models. The control experts at ENTRUST\u00a0will\u00a0design a test procedure for the specific nature of your on-site controls.\u00a0\u00a0<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/p>\n<p>&nbsp;<\/p>\n<p><b><span data-contrast=\"none\">Q5: My solar facility was commissioned in 2020. Do I need to provide EMT models?<\/span><\/b><span data-ccp-props=\"{&quot;134245418&quot;:true,&quot;134245529&quot;:true,&quot;335559738&quot;:200,&quot;335559739&quot;:0}\">\u00a0<\/span><\/p>\n<p><b><span data-contrast=\"auto\">A:<\/span><\/b><span data-contrast=\"auto\">\u00a0It depends:<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/p>\n<ul>\n<li><span data-contrast=\"auto\">If Transmission Planner\u00a0identifies\u00a0your facility under R1, Part 1.2.1: Yes, EMT model\u00a0required<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/li>\n<li><span data-contrast=\"auto\">If Transmission Planner does NOT\u00a0identify\u00a0your facility: No EMT model\u00a0required\u00a0(only positive sequence)<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/li>\n<li><span data-contrast=\"auto\">If original equipment manufacturer no longer supports EMT models: Exempt from R3<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/li>\n<\/ul>\n<p><span data-contrast=\"auto\">Check with your Transmission Planner after they publish model requirements (by January 1, 2027).<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/p>\n<p><b><span data-contrast=\"none\">Q6: We have 4 identical 30 MVA gas turbines. Can we verify just one?<\/span><\/b><span data-ccp-props=\"{&quot;134245418&quot;:true,&quot;134245529&quot;:true,&quot;335559738&quot;:200,&quot;335559739&quot;:0}\">\u00a0<\/span><\/p>\n<p><b><span data-contrast=\"auto\">A:<\/span><\/b><span data-contrast=\"auto\">\u00a0Yes, if ALL conditions are met:<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/p>\n<ul>\n<li><span data-contrast=\"auto\">Same MVA nameplate rating (\u2713 30 MVA each)<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/li>\n<li><span data-contrast=\"auto\">Nameplate \u2264350 MVA (\u2713)<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/li>\n<li><span data-contrast=\"auto\">Same components and settings (must verify)<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/li>\n<li><span data-contrast=\"auto\">Same physical location (must verify)<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/li>\n<\/ul>\n<p><b><span data-contrast=\"auto\">Process:<\/span><\/b><span data-ccp-props=\"{}\">\u00a0<\/span><\/p>\n<ul>\n<li><span data-contrast=\"auto\">Verify one unit per MOD-026-2 requirements<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/li>\n<li><span data-contrast=\"auto\">Provide written explanation for equivalent units<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/li>\n<li><span data-contrast=\"auto\">Must verify a different unit each 10-year cycle<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/li>\n<\/ul>\n<p><b><span data-contrast=\"none\">Q7: What happens if the Transmission Planner rejects our model?<\/span><\/b><span data-ccp-props=\"{&quot;134245418&quot;:true,&quot;134245529&quot;:true,&quot;335559738&quot;:200,&quot;335559739&quot;:0}\">\u00a0<\/span><\/p>\n<p><b><span data-contrast=\"auto\">A:<\/span><\/b><span data-contrast=\"auto\">\u00a0Follow the R6 process:<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/p>\n<ol>\n<li><span data-contrast=\"auto\">Transmission Planner provides (within\u00a0120\u00a0days):<\/span><span data-ccp-props=\"{}\">\u00a0<\/span>\n<ul>\n<li><span data-contrast=\"auto\">Written notification model is &#8220;not usable&#8221;<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/li>\n<li><span data-contrast=\"auto\">Technical description of issues<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/li>\n<li><span data-contrast=\"auto\">Supporting evidence<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/li>\n<\/ul>\n<\/li>\n<li><span data-contrast=\"auto\">You must respond (within 90 days) with ONE of:<\/span><span data-ccp-props=\"{}\">\u00a0<\/span>\n<ul>\n<li><span data-contrast=\"auto\">Updated model and documentation (per R2\/R3)<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/li>\n<li><span data-contrast=\"auto\">Technical justification for\u00a0maintaining\u00a0current model<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/li>\n<li><span data-contrast=\"auto\">Plan to perform model verification<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/li>\n<\/ul>\n<\/li>\n<li><span data-contrast=\"auto\">If you\u00a0submit\u00a0updated model:<\/span><span data-ccp-props=\"{}\">\u00a0<\/span>\n<ul>\n<li><span data-contrast=\"auto\">Transmission Planner has\u00a0120 days\u00a0to review<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/li>\n<li><span data-contrast=\"auto\">Process repeats until model is accepted<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/li>\n<\/ul>\n<\/li>\n<\/ol>\n<p><b><span data-contrast=\"none\">Q8: Do we need to notify the Transmission Planner about every software update?<\/span><\/b><span data-ccp-props=\"{&quot;134245418&quot;:true,&quot;134245529&quot;:true,&quot;335559738&quot;:200,&quot;335559739&quot;:0}\">\u00a0<\/span><\/p>\n<p><b><span data-contrast=\"auto\">A:<\/span><\/b><span data-contrast=\"auto\">\u00a0Only if it\u00a0<\/span><b><span data-contrast=\"auto\">alters dynamic response characteristics<\/span><\/b><span data-contrast=\"auto\">.<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/p>\n<p>Examples that REQUIRE notification:<\/p>\n<ul>\n<li><span data-contrast=\"auto\">Inverter control software update changing voltage control algorithm<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/li>\n<li><span data-contrast=\"auto\">Power Plant Controller reactive droop\u00a0or gain\u00a0changes<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/li>\n<li><span data-contrast=\"auto\">Protective function threshold changes<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/li>\n<\/ul>\n<p>Examples that DO NOT require notification:<\/p>\n<ul>\n<li><span data-contrast=\"auto\">HMI software updates<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/li>\n<li><span data-contrast=\"auto\">Monitoring system updates<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/li>\n<li><span data-contrast=\"auto\">Data historian software<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/li>\n<\/ul>\n<p><b><span data-contrast=\"none\">Q9: How do I know which protective and limiting functions to include?<\/span><\/b><span data-ccp-props=\"{&quot;134245418&quot;:true,&quot;134245529&quot;:true,&quot;335559738&quot;:200,&quot;335559739&quot;:0}\">\u00a0<\/span><\/p>\n<p><b><span data-contrast=\"auto\">A:<\/span><\/b><span data-contrast=\"auto\">\u00a0Wait for Transmission Planner requirements (R1, due by January 1, 2027).<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/p>\n<p><span data-contrast=\"auto\">The Transmission Planner will specify which functions from Attachment 1 must be modeled:<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/p>\n<ul>\n<li><span data-contrast=\"auto\">Table 1.1 for synchronous machines<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/li>\n<li><span data-contrast=\"auto\">Table 1.2 for IBRs, FACTS, HVDC<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/li>\n<\/ul>\n<h3 aria-level=\"1\"><\/h3>\n<h3 aria-level=\"1\"><b><span data-contrast=\"none\">Additional Resources<\/span><\/b><span data-ccp-props=\"{&quot;134245418&quot;:true,&quot;134245529&quot;:true,&quot;335559738&quot;:480,&quot;335559739&quot;:0}\">\u00a0<\/span><\/h3>\n<h4 aria-level=\"3\"><b><span data-contrast=\"none\">NERC Standards &amp; Documents:<\/span><\/b><span data-ccp-props=\"{&quot;134245418&quot;:true,&quot;134245529&quot;:true,&quot;335559738&quot;:200,&quot;335559739&quot;:0}\">\u00a0<\/span><\/h4>\n<ul>\n<li><span data-contrast=\"auto\">MOD-026-2 Standard (Final Draft October 2025)<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/li>\n<li><span data-contrast=\"auto\">MOD-026-2 Implementation Plan<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/li>\n<li><span data-contrast=\"auto\">MOD-026-2 Technical Rationale Document<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/li>\n<li><span data-contrast=\"auto\">FERC Order No. 901 (October 2023)<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/li>\n<li><span data-contrast=\"auto\">NERC Project 2020-06 webpage<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/li>\n<\/ul>\n<h4 aria-level=\"3\"><b><span data-contrast=\"none\">Related Standards\u00a0and Projects:<\/span><\/b><span data-ccp-props=\"{&quot;134245418&quot;:true,&quot;134245529&quot;:true,&quot;335559738&quot;:200,&quot;335559739&quot;:0}\">\u00a0<\/span><\/h4>\n<ul>\n<li><span data-contrast=\"auto\">MOD-032-1: Data for Power System Modeling<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/li>\n<li><span data-contrast=\"auto\">MOD-033-2: Steady-State and Dynamic System Model Validation<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/li>\n<li><span data-contrast=\"auto\">Project 2022-02: Uniform Modeling Framework for IBR<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/li>\n<li><span data-contrast=\"auto\">Project 2021-01: System Model Validation with IBRs<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/li>\n<\/ul>\n<h5 aria-level=\"3\"><b><span data-contrast=\"none\">Definitions:<\/span><\/b><span data-ccp-props=\"{&quot;134245418&quot;:true,&quot;134245529&quot;:true,&quot;335559738&quot;:200,&quot;335559739&quot;:0}\">\u00a0<\/span><\/h5>\n<ul>\n<li><span data-contrast=\"auto\">NERC Glossary of Terms<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/li>\n<li><span data-contrast=\"auto\">BES Definition (with Inclusions I2, I4, I5)<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/li>\n<\/ul>\n<h4 aria-level=\"3\"><b><span data-contrast=\"none\">Technical References:<\/span><\/b><span data-ccp-props=\"{&quot;134245418&quot;:true,&quot;134245529&quot;:true,&quot;335559738&quot;:200,&quot;335559739&quot;:0}\">\u00a0<\/span><\/h4>\n<ul>\n<li><span data-contrast=\"auto\">IEEE 421.5: Excitation System Models for Power System Stability Studies<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/li>\n<li><span data-contrast=\"auto\">IEEE Task Force Reports on IBR Modeling<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/li>\n<li><span data-contrast=\"auto\">NERC GADS Data Reporting Instructions (Appendix F &#8211; Capacity Factor)<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/li>\n<\/ul>\n<h3 aria-level=\"1\"><b><span data-contrast=\"none\">Conclusion<\/span><\/b><span data-ccp-props=\"{&quot;134245418&quot;:true,&quot;134245529&quot;:true,&quot;335559738&quot;:480,&quot;335559739&quot;:0}\">\u00a0<\/span><\/h3>\n<p><span data-contrast=\"auto\">MOD-026-2\u00a0represents\u00a0a\u00a0<\/span><b><span data-contrast=\"auto\">paradigm shift<\/span><\/b><span data-contrast=\"auto\">\u00a0in reliability standard requirements for dynamic modeling, primarily driven by the proliferation of Inverter-Based Resources on the Bulk Electric System. The standard:<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/p>\n<p><span data-contrast=\"auto\">\u2713\u00a0<\/span><b><span data-contrast=\"auto\">Consolidates<\/span><\/b><span data-contrast=\"auto\">\u00a0two\u00a0previous\u00a0standards into one comprehensive requirement<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/p>\n<p><span data-contrast=\"auto\">\u2713\u00a0<\/span><b><span data-contrast=\"auto\">Expands<\/span><\/b><span data-contrast=\"auto\">\u00a0scope to explicitly cover IBRs, HVDC, and FACTS<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/p>\n<p><span data-contrast=\"auto\">\u2713\u00a0<\/span><b><span data-contrast=\"auto\">Introduces<\/span><\/b><span data-contrast=\"auto\">\u00a0EMT modeling requirements for power-electronic-based facilities<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/p>\n<p><span data-contrast=\"auto\">\u2713\u00a0<\/span><b><span data-contrast=\"auto\">Clarifies<\/span><\/b><span data-contrast=\"auto\">\u00a0distinction between verification and validation<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/p>\n<p><span data-contrast=\"auto\">\u2713\u00a0<\/span><b><span data-contrast=\"auto\">Maintains<\/span><\/b><span data-contrast=\"auto\">\u00a010-year verification cycle with proven flexibility provisions<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/p>\n<p><b><span data-contrast=\"none\">Critical Success Factors:<\/span><\/b><span data-ccp-props=\"{&quot;134245418&quot;:true,&quot;134245529&quot;:true,&quot;335559738&quot;:200,&quot;335559739&quot;:0}\">\u00a0<\/span><\/p>\n<ul>\n<li><span data-contrast=\"auto\">Early manufacturer engagement for EMT models<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/li>\n<li><span data-contrast=\"auto\">Adequate budget allocation for testing and model acquisition<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/li>\n<li><span data-contrast=\"auto\">Staff training on EMT modeling and IBR technology<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/li>\n<li><span data-contrast=\"auto\">Proactive data collection through recording equipment<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/li>\n<li><span data-contrast=\"auto\">Organized documentation management for long-term compliance<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/li>\n<\/ul>\n<h4 aria-level=\"3\"><b><span data-contrast=\"none\">Immediate Next Steps:<\/span><\/b><span data-ccp-props=\"{&quot;134245418&quot;:true,&quot;134245529&quot;:true,&quot;335559738&quot;:200,&quot;335559739&quot;:0}\">\u00a0<\/span><\/h4>\n<p><b><span data-contrast=\"auto\">For Generator\/Transmission Owners:<\/span><\/b><span data-ccp-props=\"{}\">\u00a0<\/span><\/p>\n<ul>\n<li><span data-contrast=\"auto\">Begin facility applicability assessment in Q1 2026<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/li>\n<li><span data-contrast=\"auto\">Contact manufacturers for EMT model availability in Q1 2026<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/li>\n<li><span data-contrast=\"auto\">Budget for compliance costs in FY2026-2029 (major expenditures in FY2027-2028)<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/li>\n<li><span data-contrast=\"auto\">Contact\u00a0ENTRUST\u00a0for testing and model integration\/validation Q2 2027<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/li>\n<li><span data-contrast=\"auto\">Monitor for Transmission Planner requirements publication (by January 1, 2027)<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/li>\n<\/ul>\n<p><b><span data-contrast=\"auto\">Timeline:<\/span><\/b><span data-contrast=\"auto\">\u00a0With an effective date of\u00a0<\/span><b><span data-contrast=\"auto\">January 1,\u00a02026<\/span><\/b><span data-contrast=\"auto\">\u00a0and full compliance required by\u00a0<\/span><b><span data-contrast=\"auto\">January 1, 2030<\/span><\/b><span data-contrast=\"auto\">, Generator and Transmission Owners have exactly 4 years to complete all model verification, validation, and submission activities. Preparation activities should begin\u00a0immediately\u00a0in Q1 2026 to ensure adequate time for manufacturer engagement, model acquisition, testing, and validation.<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Consolidation and Expansion of Dynamic Model Verification Standards\u00a0 Effective Date: January 1, 2026 The North American Electric Reliability Corporation (NERC) has approved a major update to dynamic model verification and validation requirements. MOD-026-2\u00a0consolidates\u00a0and replaces MOD-026-1 and MOD-027-1, unifying voltage\/reactive power and frequency\/active power control into a single, comprehensive standard. Driven by FERC Order No. 901, [&hellip;]<\/p>\n","protected":false},"author":20,"featured_media":21560,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"om_disable_all_campaigns":false,"_monsterinsights_skip_tracking":false,"_monsterinsights_sitenote_active":false,"_monsterinsights_sitenote_note":"","_monsterinsights_sitenote_category":0,"wds_primary_category":0,"footnotes":""},"categories":[33],"tags":[],"class_list":["post-21552","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-blog"],"acf":[],"aioseo_notices":[],"aioseo_head":"\n\t\t<!-- All in One SEO Pro 4.8.9 - aioseo.com -->\n\t<meta name=\"description\" content=\"Consolidation and Expansion of Dynamic Model Verification Standards Effective Date: January 1, 2026 The North American Electric Reliability Corporation (NERC) has approved a major update to dynamic model verification and validation requirements. MOD-026-2 consolidates and replaces MOD-026-1 and MOD-027-1, unifying voltage\/reactive power and frequency\/active power control into a single, comprehensive standard. Driven by FERC Order No. 901,\" \/>\n\t<meta name=\"robots\" content=\"max-image-preview:large\" \/>\n\t<meta name=\"author\" content=\"Ali_ENTRUST\"\/>\n\t<link rel=\"canonical\" href=\"https:\/\/entrustsol.com\/understanding-nerc-mod-026-2\/\" \/>\n\t<meta name=\"generator\" content=\"All in One SEO Pro (AIOSEO) 4.8.9\" \/>\n\t\t<meta property=\"og:locale\" content=\"en_US\" \/>\n\t\t<meta property=\"og:site_name\" content=\"ENTRUST Solutions Group |\" \/>\n\t\t<meta property=\"og:type\" content=\"article\" \/>\n\t\t<meta property=\"og:title\" content=\"Understanding NERC MOD-026-2 | ENTRUST Solutions Group\" \/>\n\t\t<meta property=\"og:description\" content=\"Consolidation and Expansion of Dynamic Model Verification Standards Effective Date: January 1, 2026 The North American Electric Reliability Corporation (NERC) has approved a major update to dynamic model verification and validation requirements. MOD-026-2 consolidates and replaces MOD-026-1 and MOD-027-1, unifying voltage\/reactive power and frequency\/active power control into a single, comprehensive standard. Driven by FERC Order No. 901,\" \/>\n\t\t<meta property=\"og:url\" content=\"https:\/\/entrustsol.com\/understanding-nerc-mod-026-2\/\" \/>\n\t\t<meta property=\"og:image\" content=\"https:\/\/entrustsol.com\/wp-content\/uploads\/2025\/11\/AdobeStock_276818539.jpg\" \/>\n\t\t<meta property=\"og:image:secure_url\" content=\"https:\/\/entrustsol.com\/wp-content\/uploads\/2025\/11\/AdobeStock_276818539.jpg\" \/>\n\t\t<meta property=\"og:image:width\" content=\"7360\" \/>\n\t\t<meta property=\"og:image:height\" content=\"4912\" \/>\n\t\t<meta property=\"article:published_time\" content=\"2025-11-04T20:25:57+00:00\" \/>\n\t\t<meta property=\"article:modified_time\" content=\"2025-11-04T20:29:09+00:00\" \/>\n\t\t<meta property=\"article:publisher\" content=\"https:\/\/facebook.com\/entrustsolutionsgroup\" \/>\n\t\t<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n\t\t<meta name=\"twitter:site\" content=\"@entrustsol\" \/>\n\t\t<meta name=\"twitter:title\" content=\"Understanding NERC MOD-026-2 | ENTRUST Solutions Group\" \/>\n\t\t<meta name=\"twitter:description\" content=\"Consolidation and Expansion of Dynamic Model Verification Standards Effective Date: January 1, 2026 The North American Electric Reliability Corporation (NERC) has approved a major update to dynamic model verification and validation requirements. MOD-026-2 consolidates and replaces MOD-026-1 and MOD-027-1, unifying voltage\/reactive power and frequency\/active power control into a single, comprehensive standard. Driven by FERC Order No. 901,\" \/>\n\t\t<meta name=\"twitter:creator\" content=\"@entrustsol\" \/>\n\t\t<meta name=\"twitter:image\" content=\"https:\/\/entrusts3.sg-host.com\/wp-content\/uploads\/2022\/07\/EntrustLogo400x400-002.jpg\" \/>\n\t\t<script type=\"application\/ld+json\" class=\"aioseo-schema\">\n\t\t\t{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"BlogPosting\",\"@id\":\"https:\\\/\\\/entrustsol.com\\\/understanding-nerc-mod-026-2\\\/#blogposting\",\"name\":\"Understanding NERC MOD-026-2 | ENTRUST Solutions Group\",\"headline\":\"Understanding NERC MOD-026-2\",\"author\":{\"@id\":\"https:\\\/\\\/entrustsol.com\\\/author\\\/ali_entrust\\\/#author\"},\"publisher\":{\"@id\":\"https:\\\/\\\/entrustsol.com\\\/#organization\"},\"image\":{\"@type\":\"ImageObject\",\"url\":\"https:\\\/\\\/entrustsol.com\\\/wp-content\\\/uploads\\\/2025\\\/11\\\/AdobeStock_276818539.jpg\",\"width\":7360,\"height\":4912},\"datePublished\":\"2025-11-04T14:25:57-06:00\",\"dateModified\":\"2025-11-04T14:29:09-06:00\",\"inLanguage\":\"en-US\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/entrustsol.com\\\/understanding-nerc-mod-026-2\\\/#webpage\"},\"isPartOf\":{\"@id\":\"https:\\\/\\\/entrustsol.com\\\/understanding-nerc-mod-026-2\\\/#webpage\"},\"articleSection\":\"Blog\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/entrustsol.com\\\/understanding-nerc-mod-026-2\\\/#breadcrumblist\",\"itemListElement\":[{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/entrustsol.com#listItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/entrustsol.com\",\"nextItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/entrustsol.com\\\/category\\\/blog\\\/#listItem\",\"name\":\"Blog\"}},{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/entrustsol.com\\\/category\\\/blog\\\/#listItem\",\"position\":2,\"name\":\"Blog\",\"item\":\"https:\\\/\\\/entrustsol.com\\\/category\\\/blog\\\/\",\"nextItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/entrustsol.com\\\/understanding-nerc-mod-026-2\\\/#listItem\",\"name\":\"Understanding NERC MOD-026-2\"},\"previousItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/entrustsol.com#listItem\",\"name\":\"Home\"}},{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/entrustsol.com\\\/understanding-nerc-mod-026-2\\\/#listItem\",\"position\":3,\"name\":\"Understanding NERC MOD-026-2\",\"previousItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/entrustsol.com\\\/category\\\/blog\\\/#listItem\",\"name\":\"Blog\"}}]},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/entrustsol.com\\\/#organization\",\"name\":\"ENTRUST Solutions Group\",\"url\":\"https:\\\/\\\/entrustsol.com\\\/\",\"telephone\":\"+16303534000\",\"logo\":{\"@type\":\"ImageObject\",\"url\":\"https:\\\/\\\/entrusts3.sg-host.com\\\/wp-content\\\/uploads\\\/2022\\\/06\\\/cropped-EntrustLogo-1.png\",\"@id\":\"https:\\\/\\\/entrustsol.com\\\/understanding-nerc-mod-026-2\\\/#organizationLogo\"},\"image\":{\"@id\":\"https:\\\/\\\/entrustsol.com\\\/understanding-nerc-mod-026-2\\\/#organizationLogo\"},\"sameAs\":[\"https:\\\/\\\/twitter.com\\\/entrustsol\",\"https:\\\/\\\/www.youtube.com\\\/channel\\\/UCatEblW8z_HBod23zlUKIGQ\",\"https:\\\/\\\/www.linkedin.com\\\/company\\\/entrustsolutionsgroup\"]},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/entrustsol.com\\\/author\\\/ali_entrust\\\/#author\",\"url\":\"https:\\\/\\\/entrustsol.com\\\/author\\\/ali_entrust\\\/\",\"name\":\"Ali_ENTRUST\",\"image\":{\"@type\":\"ImageObject\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/27b5529187d79a8012256e34898654432ad9efb294c70f745f79c36de0b72ab3?s=96&d=mm&r=g\"}},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/entrustsol.com\\\/understanding-nerc-mod-026-2\\\/#webpage\",\"url\":\"https:\\\/\\\/entrustsol.com\\\/understanding-nerc-mod-026-2\\\/\",\"name\":\"Understanding NERC MOD-026-2 | ENTRUST Solutions Group\",\"description\":\"Consolidation and Expansion of Dynamic Model Verification Standards Effective Date: January 1, 2026 The North American Electric Reliability Corporation (NERC) has approved a major update to dynamic model verification and validation requirements. MOD-026-2 consolidates and replaces MOD-026-1 and MOD-027-1, unifying voltage\\\/reactive power and frequency\\\/active power control into a single, comprehensive standard. Driven by FERC Order No. 901,\",\"inLanguage\":\"en-US\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/entrustsol.com\\\/#website\"},\"breadcrumb\":{\"@id\":\"https:\\\/\\\/entrustsol.com\\\/understanding-nerc-mod-026-2\\\/#breadcrumblist\"},\"author\":{\"@id\":\"https:\\\/\\\/entrustsol.com\\\/author\\\/ali_entrust\\\/#author\"},\"creator\":{\"@id\":\"https:\\\/\\\/entrustsol.com\\\/author\\\/ali_entrust\\\/#author\"},\"image\":{\"@type\":\"ImageObject\",\"url\":\"https:\\\/\\\/entrustsol.com\\\/wp-content\\\/uploads\\\/2025\\\/11\\\/AdobeStock_276818539.jpg\",\"@id\":\"https:\\\/\\\/entrustsol.com\\\/understanding-nerc-mod-026-2\\\/#mainImage\",\"width\":7360,\"height\":4912},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/entrustsol.com\\\/understanding-nerc-mod-026-2\\\/#mainImage\"},\"datePublished\":\"2025-11-04T14:25:57-06:00\",\"dateModified\":\"2025-11-04T14:29:09-06:00\"},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/entrustsol.com\\\/#website\",\"url\":\"https:\\\/\\\/entrustsol.com\\\/\",\"name\":\"ENTRUST Solutions Group\",\"inLanguage\":\"en-US\",\"publisher\":{\"@id\":\"https:\\\/\\\/entrustsol.com\\\/#organization\"}}]}\n\t\t<\/script>\n\t\t<!-- All in One SEO Pro -->\r\n\t\t<title>Understanding NERC MOD-026-2 | ENTRUST Solutions Group<\/title>\n\n","aioseo_head_json":{"title":"Understanding NERC MOD-026-2 | ENTRUST Solutions Group","description":"Consolidation and Expansion of Dynamic Model Verification Standards Effective Date: January 1, 2026 The North American Electric Reliability Corporation (NERC) has approved a major update to dynamic model verification and validation requirements. MOD-026-2 consolidates and replaces MOD-026-1 and MOD-027-1, unifying voltage\/reactive power and frequency\/active power control into a single, comprehensive standard. Driven by FERC Order No. 901,","canonical_url":"https:\/\/entrustsol.com\/understanding-nerc-mod-026-2\/","robots":"max-image-preview:large","keywords":"","webmasterTools":{"miscellaneous":""},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"BlogPosting","@id":"https:\/\/entrustsol.com\/understanding-nerc-mod-026-2\/#blogposting","name":"Understanding NERC MOD-026-2 | ENTRUST Solutions Group","headline":"Understanding NERC MOD-026-2","author":{"@id":"https:\/\/entrustsol.com\/author\/ali_entrust\/#author"},"publisher":{"@id":"https:\/\/entrustsol.com\/#organization"},"image":{"@type":"ImageObject","url":"https:\/\/entrustsol.com\/wp-content\/uploads\/2025\/11\/AdobeStock_276818539.jpg","width":7360,"height":4912},"datePublished":"2025-11-04T14:25:57-06:00","dateModified":"2025-11-04T14:29:09-06:00","inLanguage":"en-US","mainEntityOfPage":{"@id":"https:\/\/entrustsol.com\/understanding-nerc-mod-026-2\/#webpage"},"isPartOf":{"@id":"https:\/\/entrustsol.com\/understanding-nerc-mod-026-2\/#webpage"},"articleSection":"Blog"},{"@type":"BreadcrumbList","@id":"https:\/\/entrustsol.com\/understanding-nerc-mod-026-2\/#breadcrumblist","itemListElement":[{"@type":"ListItem","@id":"https:\/\/entrustsol.com#listItem","position":1,"name":"Home","item":"https:\/\/entrustsol.com","nextItem":{"@type":"ListItem","@id":"https:\/\/entrustsol.com\/category\/blog\/#listItem","name":"Blog"}},{"@type":"ListItem","@id":"https:\/\/entrustsol.com\/category\/blog\/#listItem","position":2,"name":"Blog","item":"https:\/\/entrustsol.com\/category\/blog\/","nextItem":{"@type":"ListItem","@id":"https:\/\/entrustsol.com\/understanding-nerc-mod-026-2\/#listItem","name":"Understanding NERC MOD-026-2"},"previousItem":{"@type":"ListItem","@id":"https:\/\/entrustsol.com#listItem","name":"Home"}},{"@type":"ListItem","@id":"https:\/\/entrustsol.com\/understanding-nerc-mod-026-2\/#listItem","position":3,"name":"Understanding NERC MOD-026-2","previousItem":{"@type":"ListItem","@id":"https:\/\/entrustsol.com\/category\/blog\/#listItem","name":"Blog"}}]},{"@type":"Organization","@id":"https:\/\/entrustsol.com\/#organization","name":"ENTRUST Solutions Group","url":"https:\/\/entrustsol.com\/","telephone":"+16303534000","logo":{"@type":"ImageObject","url":"https:\/\/entrusts3.sg-host.com\/wp-content\/uploads\/2022\/06\/cropped-EntrustLogo-1.png","@id":"https:\/\/entrustsol.com\/understanding-nerc-mod-026-2\/#organizationLogo"},"image":{"@id":"https:\/\/entrustsol.com\/understanding-nerc-mod-026-2\/#organizationLogo"},"sameAs":["https:\/\/twitter.com\/entrustsol","https:\/\/www.youtube.com\/channel\/UCatEblW8z_HBod23zlUKIGQ","https:\/\/www.linkedin.com\/company\/entrustsolutionsgroup"]},{"@type":"Person","@id":"https:\/\/entrustsol.com\/author\/ali_entrust\/#author","url":"https:\/\/entrustsol.com\/author\/ali_entrust\/","name":"Ali_ENTRUST","image":{"@type":"ImageObject","url":"https:\/\/secure.gravatar.com\/avatar\/27b5529187d79a8012256e34898654432ad9efb294c70f745f79c36de0b72ab3?s=96&d=mm&r=g"}},{"@type":"WebPage","@id":"https:\/\/entrustsol.com\/understanding-nerc-mod-026-2\/#webpage","url":"https:\/\/entrustsol.com\/understanding-nerc-mod-026-2\/","name":"Understanding NERC MOD-026-2 | ENTRUST Solutions Group","description":"Consolidation and Expansion of Dynamic Model Verification Standards Effective Date: January 1, 2026 The North American Electric Reliability Corporation (NERC) has approved a major update to dynamic model verification and validation requirements. MOD-026-2 consolidates and replaces MOD-026-1 and MOD-027-1, unifying voltage\/reactive power and frequency\/active power control into a single, comprehensive standard. Driven by FERC Order No. 901,","inLanguage":"en-US","isPartOf":{"@id":"https:\/\/entrustsol.com\/#website"},"breadcrumb":{"@id":"https:\/\/entrustsol.com\/understanding-nerc-mod-026-2\/#breadcrumblist"},"author":{"@id":"https:\/\/entrustsol.com\/author\/ali_entrust\/#author"},"creator":{"@id":"https:\/\/entrustsol.com\/author\/ali_entrust\/#author"},"image":{"@type":"ImageObject","url":"https:\/\/entrustsol.com\/wp-content\/uploads\/2025\/11\/AdobeStock_276818539.jpg","@id":"https:\/\/entrustsol.com\/understanding-nerc-mod-026-2\/#mainImage","width":7360,"height":4912},"primaryImageOfPage":{"@id":"https:\/\/entrustsol.com\/understanding-nerc-mod-026-2\/#mainImage"},"datePublished":"2025-11-04T14:25:57-06:00","dateModified":"2025-11-04T14:29:09-06:00"},{"@type":"WebSite","@id":"https:\/\/entrustsol.com\/#website","url":"https:\/\/entrustsol.com\/","name":"ENTRUST Solutions Group","inLanguage":"en-US","publisher":{"@id":"https:\/\/entrustsol.com\/#organization"}}]},"og:locale":"en_US","og:site_name":"ENTRUST Solutions Group |","og:type":"article","og:title":"Understanding NERC MOD-026-2 | ENTRUST Solutions Group","og:description":"Consolidation and Expansion of Dynamic Model Verification Standards Effective Date: January 1, 2026 The North American Electric Reliability Corporation (NERC) has approved a major update to dynamic model verification and validation requirements. MOD-026-2 consolidates and replaces MOD-026-1 and MOD-027-1, unifying voltage\/reactive power and frequency\/active power control into a single, comprehensive standard. Driven by FERC Order No. 901,","og:url":"https:\/\/entrustsol.com\/understanding-nerc-mod-026-2\/","og:image":"https:\/\/entrustsol.com\/wp-content\/uploads\/2025\/11\/AdobeStock_276818539.jpg","og:image:secure_url":"https:\/\/entrustsol.com\/wp-content\/uploads\/2025\/11\/AdobeStock_276818539.jpg","og:image:width":7360,"og:image:height":4912,"article:published_time":"2025-11-04T20:25:57+00:00","article:modified_time":"2025-11-04T20:29:09+00:00","article:publisher":"https:\/\/facebook.com\/entrustsolutionsgroup","twitter:card":"summary_large_image","twitter:site":"@entrustsol","twitter:title":"Understanding NERC MOD-026-2 | ENTRUST Solutions Group","twitter:description":"Consolidation and Expansion of Dynamic Model Verification Standards Effective Date: January 1, 2026 The North American Electric Reliability Corporation (NERC) has approved a major update to dynamic model verification and validation requirements. MOD-026-2 consolidates and replaces MOD-026-1 and MOD-027-1, unifying voltage\/reactive power and frequency\/active power control into a single, comprehensive standard. Driven by FERC Order No. 901,","twitter:creator":"@entrustsol","twitter:image":"https:\/\/entrusts3.sg-host.com\/wp-content\/uploads\/2022\/07\/EntrustLogo400x400-002.jpg"},"aioseo_meta_data":{"post_id":"21552","title":null,"description":null,"keywords":null,"keyphrases":{"focus":{"keyphrase":"","score":0,"analysis":{"keyphraseInTitle":{"score":0,"maxScore":9,"error":1}}},"additional":[]},"primary_term":null,"canonical_url":null,"og_title":null,"og_description":null,"og_object_type":"default","og_image_type":"default","og_image_url":null,"og_image_width":null,"og_image_height":null,"og_image_custom_url":null,"og_image_custom_fields":null,"og_video":"","og_custom_url":null,"og_article_section":null,"og_article_tags":null,"twitter_use_og":false,"twitter_card":"default","twitter_image_type":"default","twitter_image_url":null,"twitter_image_custom_url":null,"twitter_image_custom_fields":null,"twitter_title":null,"twitter_description":null,"schema":{"blockGraphs":[],"customGraphs":[],"default":{"data":{"Article":[],"Course":[],"Dataset":[],"FAQPage":[],"Movie":[],"Person":[],"Product":[],"ProductReview":[],"Car":[],"Recipe":[],"Service":[],"SoftwareApplication":[],"WebPage":[]},"graphName":"BlogPosting","isEnabled":true},"graphs":[]},"schema_type":"default","schema_type_options":null,"pillar_content":false,"robots_default":true,"robots_noindex":false,"robots_noarchive":false,"robots_nosnippet":false,"robots_nofollow":false,"robots_noimageindex":false,"robots_noodp":false,"robots_notranslate":false,"robots_max_snippet":"-1","robots_max_videopreview":"-1","robots_max_imagepreview":"large","priority":null,"frequency":"default","local_seo":null,"seo_analyzer_scan_date":"2025-11-04 20:34:41","breadcrumb_settings":null,"limit_modified_date":false,"reviewed_by":"0","open_ai":null,"ai":{"faqs":[],"keyPoints":[],"titles":[],"descriptions":[],"socialPosts":{"email":[],"linkedin":[],"twitter":[],"facebook":[],"instagram":[]}},"created":"2025-11-04 14:17:44","updated":"2025-11-04 20:48:59"},"aioseo_breadcrumb":"<div class=\"aioseo-breadcrumbs\"><span class=\"aioseo-breadcrumb\">\n\t<a href=\"https:\/\/entrustsol.com\" title=\"Home\">Home<\/a>\n<\/span><span class=\"aioseo-breadcrumb-separator\">&raquo;<\/span><span class=\"aioseo-breadcrumb\">\n\t<a href=\"https:\/\/entrustsol.com\/category\/blog\/\" title=\"Blog\">Blog<\/a>\n<\/span><span class=\"aioseo-breadcrumb-separator\">&raquo;<\/span><span class=\"aioseo-breadcrumb\">\n\tUnderstanding NERC MOD-026-2\n<\/span><\/div>","aioseo_breadcrumb_json":[{"label":"Home","link":"https:\/\/entrustsol.com"},{"label":"Blog","link":"https:\/\/entrustsol.com\/category\/blog\/"},{"label":"Understanding NERC MOD-026-2","link":"https:\/\/entrustsol.com\/understanding-nerc-mod-026-2\/"}],"_links":{"self":[{"href":"https:\/\/entrustsol.com\/wp-json\/wp\/v2\/posts\/21552","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/entrustsol.com\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/entrustsol.com\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/entrustsol.com\/wp-json\/wp\/v2\/users\/20"}],"replies":[{"embeddable":true,"href":"https:\/\/entrustsol.com\/wp-json\/wp\/v2\/comments?post=21552"}],"version-history":[{"count":12,"href":"https:\/\/entrustsol.com\/wp-json\/wp\/v2\/posts\/21552\/revisions"}],"predecessor-version":[{"id":21653,"href":"https:\/\/entrustsol.com\/wp-json\/wp\/v2\/posts\/21552\/revisions\/21653"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/entrustsol.com\/wp-json\/wp\/v2\/media\/21560"}],"wp:attachment":[{"href":"https:\/\/entrustsol.com\/wp-json\/wp\/v2\/media?parent=21552"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/entrustsol.com\/wp-json\/wp\/v2\/categories?post=21552"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/entrustsol.com\/wp-json\/wp\/v2\/tags?post=21552"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}